TEC29, TEC29LPG Operating the generator
17
Displays
8 Operating the generator
A
I
8.1 Basic notes on operation
!
Please note the following basic information:
• Always check the oil level before use (chapter “Checking the oil level” on
page 21).
• TEC29LPG only: Check there are no leaks from the gas supply using a leak
detection spray before every use.
• Even small overloads in the long-run will cause the cut-out switch (TEC29) or the
fuses (TEC29LPG) to trigger.
No. in
fig. 3,
page 4
Description
6 AC supply Actual voltage output
7 Constant output Current capacity of connected consumer
8 Operating hours Time the generator is in operation
9 DC voltage Battery voltage
10 Messages Status reports of the generator (see chapter
“Display messages” on page 19)
NOTICE!
Do not run the generator over 70 % of the maximum constant output for
the first 50 operating hours (run-in phase).
NOTE
Run the generator at a maximum of approx. 75 % of the maximum con-
tinuous load after the run-in phase.
By doing this you can prolong the service life of the generator and max-
imise its efficiency.
CAUTION! Beware of injury
Do not insert your fingers or objects into the air nozzles or the intake
grille.