Troubleshooting TEC29, TEC29LPG
30
The generator
tends to stall.
Too much oil in the engine.
➤ Drain the oil.
Load is over 2.6 kW.
➤ Reduce the consumers.
Carburettor is not receiving any petrol.
➤ Clean the carburettor.
Air intake is blocked.
➤ Check the air filter (see chapter
“Servicing the air filter (fig. 7,
page 6)” on page 27).
Inverter is damaged.
➤ Contact an authorised workshop.
Electromagnet is blocked.
Air filter is dirty.
The generator is
running but does
not supply any volt-
age.
Inverter is damaged.
➤ Contact an authorised workshop.
The stepper motor is faulty or the cable is
disconnected.
Electromagnet is blocked.
The throttle valve is blocked.
The generator
starts up very fast
and then the
“GENERATOR
ALERT” message
appears.
Inverter is damaged.
➤ Contact an authorised workshop.
The stepper motor is faulty or the cable is
disconnected.
The generated
voltage is unstable.
Inverter is damaged.
➤ Contact an authorised workshop.
The stepper motor is faulty or the cable is
disconnected.
Fault Cause Remedy
TEC29-B-16s.book Seite 30 Donnerstag, 21. Juli 2016 8:09 08