Output Voltage | 12 V DC |
---|---|
Battery Type | Lead-acid, Gel, AGM |
Charging Voltage | 14.4 V |
Protection Features | Overvoltage, short-circuit, reverse polarity, over-temperature |
Input Voltage | 100-240V AC, 50/60Hz |
Operating Temperature | -20 to +50 °C |
Safety instruction: Failure to observe this instruction will cause fatal or serious injury.
Safety instruction: Failure to observe this instruction can cause fatal or serious injury.
Safety instruction: Failure to observe this instruction can lead to injury.
Manufacturer accepts no liability for damage from faulty assembly, mechanical influences, unauthorized alterations, or misuse.
Check operating voltage matches mains voltage before first use; use fire extinguisher for electrical fires.
Do not use device or cables if visibly damaged.
Identifies Status LED and Fan based on figure references and explains their functions.
Explains meanings of LED colors and flashing patterns for different charging phases and faults.
Details the modified IU0U charging characteristics: I phase (bulk), U0 phase (absorption), U phase (float), and 12-day conditioning.
Details input voltage, frequency, efficiency, current, and starting current specifications.
Lists charging voltage, retention voltage, current, and rated power for different battery types.
Specifies protective functions like output short circuit, overvoltage, and temperature protection.