The differential pressure across each section of the system
will be displayed. A ‘System Overview’ bar graph will be
displayed to easily visualise the pressures across the system.
• Airflow: Current airflow reading
• Inlet Pressure
• Pre-Filter Pressure
• Main Filter Pressure
• Total system pressure
• Free: Available head pressure for system at current
airflow
Each section will have a traffic light warning icon indicating
the health of the section.
The page will display the systems current flow. This page as
well as the pre and main filter pages will have a pump icon
displaying the pumps state, pressing will navigate the user
to the ‘Pump Diagnostics’ this page is also accessible from
the home screen, as seen below:
OR
Each connected pump will be accessible from this page.
They can be selected by pressing the corresponding number
at the top of the page. The pump selection bar will populate
with the amount of pumps Each connected pump will be
accessible from this page. The pump selection bar will
populate with the amount of pumps connected to the
system. The page will display the following pump data:
• Speed: RPM
• Head Pressure: Pa
• Drive: Voltage or PWM (Pump Dependant)
- Beneath Drive voltage a percentage figure of how
much of the drive voltage is being used is shown.
The pump selection icons will display RED if an error has
been detected with the associated pump.
The ‘Back’ button will navigate back to the previous screen.
Filter Status
The ‘main and Pre-Filter’ pages will hold all the data
relevant to the combined filters state.
• Filter block level relative to achievable system
pressure (%)
• Pressure: Differential pressure across filter (Pa)