I/O Terminal Block 2 Layout (Gx-IC10/Gx-OEM)
Gx-IC10 and Gx-OEM Controllers have two I/O connectors.
Use a B2CF 3.5mm, 18 way, pluggable terminal block to connect to the controller's S2C terminal
block.
To define input and output functions, see I/O Function Assignment on page 82.
The pin assignment for I/O terminal block 2 is illustrated below.
Note
The layout was changed, for I/O terminal blocks on Gx-OEM controllers from
serial number E79888D0G111242 onwards, and Gx-IC10 controllers from serial
number E79961F0G111198 onwards. The terminal block layouts for controllers
that are earlier and later than these serial numbers are both listed below.
S2C 3.5mm, 18-Way, Terminal Block (External View)
Gx-OEM Serial Number E79888D0G111242 or Later, and Gx-IC10 Serial Number
E79961F0G111198 or Later.
Pin Description Pin Description
1 Alarm 1 (Normally Closed) 2 Alarm 1 (Normally Open)
3 Alarm 2 (Normally Closed) 4 Alarm 2 (Normally Open)
5 Alarm 3 (Normally Closed) 6 Alarm 3 (Normally Open)
7 Alarm Common 8 Output 24 V DC
9 External Output 2 Common 10 External Input 2 Common
11 External Output 2_1 12 External Input 2_1
13 External Output 2_2 14 External Input 2_2
15 External Output 2_3 16 External Input 2_3
17 External Output 2_4 18 External Input 2_4
Gx-OEM Serial Number E79888D0G111241 or Earlier, and Gx-IC10 E79961F0G111197 or
Earlier.
Pin Description Pin Description
1 Alarm 1 (Normally Closed) 2 Alarm 1 (Normally Open)
3 Alarm 2 (Normally Closed) 4 Alarm 2 (Normally Open)
5 Alarm 3 (Normally Closed) 6 Alarm 3 (Normally Open)