[CHAPTER 6 FUNCTION TABLE & DESCRIPTION]
6-17 |
DOOCHPUMP
dr-15 Non-load Current of Motor
It sets non-load current of motor.
Factory Setting Input Range
Initial value is set upon drive capacity 0.5 ~ 100.0 [Arms]
dr-16 Rated Slip Freq. of Motor
It displays slip freq. of motor.
Settings are automatically set upon No. of motor poles, rated No. of rotations, and rated
frequency.
Factory
Setting
Input Range
Related Function
dr-11 No. of motor poles
dr-13 Rated No. of Rotations of Motor
Automatic
Setup
0.10~10.00[Hz]
dr-17 Rated Frequency of Motor
dr-17 Rated Frequency of Motor
It sets rated frequency of motor.
Setup Data Functional Description Related Function
50[Hz] 0
1 (Factory Setting) 60[Hz]
dr-43
Max Operation
Freq.
dr-18 Efficiency of Motor
It is set when pump drive is released from the factory.
Factory Setting Input Range
Initial value is set upon drive capacity 70 ~ 100 [%]
Motor related constants (dr-10~dr-18) set upon drive capacity may not match with motor data of
the user. Be sure to check data on the nameplate.
dr-13 No. of Rated Rotations of Motor
It sets No. of rated rotations of motor. It is based on data indicated on the nameplate of the motor.
Factory Setting Input Range
Initial value is set upon drive capacity 1 ~ 9999 [rpm]
dr-14 Rated Voltage of Motor
It sets rated voltage of motor. It is based on data indicated on the nameplate of the motor.
Factory Setting Input Range
Initial value is set upon drive capacity 200.0 ~ 500.0 [Vrms]