EasyManua.ls Logo

DoorKing 1802 - Main Terminal Description; RS-485 Wiring

DoorKing 1802
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.8 Main Terminal Description
Terminal Description
1 Phone In (Negative)
2 Phone In (Positive)
3 Ground
4 Phone Out (Positive)
5 Phone Out (Negative)
6 Not Used.
7
Switch Input Relay 1. A switch closure across terminals 7 & 9 will activate relay 1 for
its programmed strike time.
8
Switch Input Relay 2. A switch closure across terminals 8 & 9 will activate relay 2 for
its programmed strike time.
9 - 12 VDC Battery Negative. Also common for terminals 7 & 8.
10 + 12 VDC Battery Positive.
11 Relay 1 Normally Open
12 Relay 1 Normally Closed
13 Relay 1 Common
14 Relay 2 Normally Open
15 Relay 2 Normally Closed
16 Relay 2 Common
17 16.5 VAC Input Power
18 16.5 VAC Input Power
Page 24 1810-162-L-5-15