EasyManua.ls Logo

DoorKing 1802 - Remote Operation; Remote Programming; Remote Relay Activation; Relay Activation Check

DoorKing 1802
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.2 Remote Operation
4.2.1 Remote Programming
The Access Plus unit can be programmed and operated from a remote location using a touch-tone
telephone. Be sure that the ability for the unit to answer an incoming call has not been disabled (see
2.4.7).
Note: The Access Plus unit master code cannot be programmed remotely it can only be
programmed from the system keypad see Programming the Master Code on page 32.
1. Call the unit’s phone number. After the programmed number of rings (2.4.7) the Access Plus
unit will answer with a tone.
2. Follow the desired programming steps in Section 2 of this manual.
3. When complete with the desired programming function, hang up. You cannot use 0# to end
programming steps from a touch-tone telephone.
4.2.2 Remote Relay Activation
The Access Plus system relays can be activated from a remote (off site) location. Be sure that the
ability for the Access Plus unit to answer an incoming call has not been disabled (see 2.4.7). Refer to
the tone open numbers that where programmed in section 2.4.6 to determine each of the activation
numbers.
Momentary Activation (Relay activates for its programmed strike time)
Hold Open (Relay will activate and remain activated).
Deactivate (Relay will deactivate)
Hold 1 Hour (Relay will activate for 1 hour and then automatically deactivate)
To activate the relay(s) from a remote (off-site) location, perform the following steps.
1. Call the phone number that the Access Plus unit is connected to. After the programmed
number of rings (2.4.7) the unit will answer with a tone.
2. Press * 1 6 and enter the MASTER CODE. [ * 1 6 _ _ _ _ (beep)]
(Two-way voice communication is also enabled at this point)
3. Enter the desired tone open number. [ _ (beep)]
4. Hang up.
1810-162-L-5-15 Page 55