4.2.3 Relay Activation Check
The Access Plus unit can be called to check if relay 1, relay 2, or both relays on the unit’s main circuit
board are latched and holding a door or gate in the open (unlocked) position.
1. Call the phone number that the Access Plus unit is connected to. After the programmed
number of rings (2.4.7) the unit will answer with a tone.
2. Press * 1 6 and enter the MASTER CODE. [ * 1 6 _ _ _ _ (beep)]
3. Press * 7. [ * 7 (beep)]
4. Listen for the following sequence of tones. No tones: neither relay is activated. Relay 1
activated: beep - pause - beep - pause . . .Relay 2 activated: beep beep - pause - beep
beep - pause . . .Both relays activated: beep beep beep - pause - beep beep beep - pause .
. .
5. Hang up.
Page 56 1810-162-L-5-15