HY-DP-MANUAL-001 20
3.9 Spare Sensor
Item
Condition
Gearbox Oil Pressure
Alarm will be activated when the gearbox oil temperature is
1bar or lower
*Boost Air Temperature
Current temperature
*Boost Air Pressure
It is normal when the boost air pressure is between 1.1bar
and 2.9bar
*Boost Air Pressure (Low)
Alarm will be activated when the boost air pressure is 1bar
or lower
*Boost Air Pressure (High)
Alarm will be activated when the boost air pressure is 3bar
or higher
*Engine Oil Over Heat
Alarm will be activated when the engine oil temperature is
150℃ or higher
Battery Voltage
Current voltage
Exhaust Air Temperature
(High)
Alarm will be activated when the exhaust air temperature is
600℃ or higher
*Water Level (Low)
Alarm will be activated when the coolant level is 30% or
lower
*Fuel Level (Low)
Alarm will be activated when the fuel level is 30% or lower
- It identifies the status of spare sensor, product S/N, F/W version, and date/time. Press button
of the function key to move to spare sensor page.
3. Part Names, Operation and Settings
Alarm On
[Fig. 3-25] Spare Sensor and SW information
* Sensor for IMO Tier 3
[Table 3-11] Spare Sensor Conditions