Starting the Engine
Prestart Conditions
NOTE: The engine will not start unless the
transmission directional control lever is in
the NEUTRAL position.
Typical Example
1. Engage the parking brake, if not already
engaged.
2. Place the transmission directional control lever
in NEUTRAL position.
NOTICE
When you restart the engine after turning off it, wait
4 to 5 seconds and restart it to protect the starter.
Diesel Engine
Starting a Cold Diesel Engine
1. Turn the ignition key to the ON position. The
start preheat light will come ON. The preheat
light will stay ON approximately seven seconds,
depending on the ambient air temperature.
NOTICE
Do not engage the starter for more than 10 seconds.
2. When the preheat light goes OFF, turn the
ignition key to the START position, with the
accelerator pedal fully depressed.
3. Release the ignition key when the engine starts
and release the accelerator pedal to a low idle
position.
4. If the engine stalls or does not start, turn the
ignition key to the OFF position, then repeat
steps 1 thru 3.
Starting a Warm Diesel Engine
1. Turn the ignition key to the ON position and then
to START position, without waiting for the
preheat light to go OFF. At the same time fully
depress the accelerator.
2. Release the ignition key when the engine starts
and release the accelerator pedal to a low idle
position.
LP Engine
WARNING
LP fuel is flammable and can cause personal
injury.
Inspect LP fuel lines and fitting for leaks.
Inspect tank for secure mounting.
1. Open the tank fuel valve by slowly turning the
valve counterclockwise. Observe the LP gauge
(if equipped).
2. Turn the ignition switch to the START position.
Release it when the engine starts.
3. If the engine does not start, Do not press on the
accelerator pedal. Turn the starter switch to OFF
position, the repeat step 2 and depress the
accelerator pedal slightly during cranking.
4. Allow the engine to warm up slowly.