EasyManua.ls Logo

Doosan D60S-5 - Page 87

Doosan D60S-5
204 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Section
86
Problem Probable Cause Corrective Action
Will Not Run
Continuously
Fuel container almost empty LPG Vapor from liquid outlet
z Fill fuel container
z Do not exceed 80% of liquid
capacity
Excess flow valve closed Reset excess flow valve
z Close liquid valve
z Wait for a “click” sound
Slowly open liquid valve
Clogged fuel filter Repair/replace as required
z See Maintenance Section, LP Fuel
Filter replacement
Plugged fuel line Remove obstruction from the fuel line
z Close liquid fuel valve
z Using caution, disconnect the fuel
line (some propane may escape)
z Clear obstruction with compressed
air
z Re-connect fuel line
z Slowly open liquid fuel valve & Leak
test
Pressure regulator freezes Check level in cooling system
z Must be full, check coolant strength
z -35F minimum
Check coolant hoses
z Watch for kinks and/or pinched
hoses
z Verify one pressure hose and one
return hose
Fuel Lock-off malfunction Repair/replace Fuel Lock-off
z See Engine Service Manual
Incorrect idle speed or ignition
problem
See Advanced Diagnostics
Engine Mechanical See Engine Service Manual
Will Not
Accelerate/Hesitat
ion During
Acceleration
Fuel container almost empty LPG Vapor from liquid outlet
z Fill fuel container
z Do not exceed 80% of liquid
capacity
Excess flow valve closed Reset excess flow valve
z Close liquid valve
z Wait for a “click” sound
z Slowly open liquid valve

Table of Contents

Other manuals for Doosan D60S-5

Related product manuals