DL06K Interim Tire-4 Diesel Engine Disassembly and Reassembly of Major Components
152
32. Camshaft sensor
P0341 DFC_EpmCaSI1ErrSig camshaft signal diagnose - disturbed signal
P0340 DFC_EpmCaSI1NoSig camshaft signal diagnose - no signal
P0340 DFC_EpmCaSI1OfsErr camshaft offset angle exceeded
33. Crankshaft sensor
P0336 DFC_EpmCrSErrSig crankshaft signal diagnose - disturbed signal
P0335 DFC_EpmCrSNoSig crankshaft signal diagnose - no signal
34. Auto fan clutch PWM out
P0480 DFC_FanDIOOL Fan : Open Load error on the output power stage.
P0484 DFC_FanDIOOvrTemp
Fan : Over Temperature error on the output
power stage
P0484 DFC_FanDIOSCB
Fan : Short Circuit to battery error on the output
power stage
P0485 DFC_FanDIOSCG
Fan : Short Circuit to Ground error on the output
power stage
P0481 DFC_FanPWMOL Fan : Open Load error on the output power stage
P0481 DFC_FanPWMOvrTemp
Fan : Over Temperature error on the output
power stage
P0694 DFC_FanPWMSCB
Fan : Short Circuit to battery error on the output
power stage
P0693 DFC_FanPWMSCG
Fan : Short Circuit to Ground error on the output
power stage
35. Auto fan clutch speed
P0526 DFC_FanSpdLonPer Fan speed signal long period fault path
P0527 DFC_FanSpdSRCHigh Fan speed signal range check high fault path
P0528 DFC_FanSpdSRCLow Fan speed signal range check low fault path
36. Fuel temperature sensor
P0181 DFC_FuelTPhysRngHi Physical Range Check high for fuel temperature
P0180 DFC_FuelTPhysRngLo Physical Range Check low for fuel temperature
P0183 DFC_FuelTSRCMax SRC high for fuel temperature sensor
P0182 DFC_FuelTSRCMin SRC low for fuel temperature sensor
37. Metering Unit Hydrocarbon dosing valve.
P1080 DFC_HCDosVlvEPHi
The current at the end of the injection phase exceeds
the maximum threshold (HCDosVlv_iEIPMax_C)
P1081 DFC_HCDosVlvOvrTemp
Over temperature error on power stage of
Hydrocarbon dosing valve actuator
P1082 DFC_HCDosVlvSCBLS
Short circuit to battery error in power stage of
Hydrocarbon dosing valve actuator
P1083 DFC_HCDosVlvSCBOLHS
short circuit to ground or open load on the
High side switch.
P1084 DFC_HCDosVlvSCGOLLS
short circuit to ground or open load on the low
side switch.
P1085 DFC_HCDosVlvSCHS
Short circuit error in high side power stage of
Hydrocarbon dosing valve actuator
38. DPM system error
P1060 DFC_HCIMonAddPresIncTstDs
Additional Pressure Increase Test Downstream
Error = FCT_ERROR in Pressure Increase
Test-Upstream state
P1061 DFC_HCIMonPresDecTstUsErr
Pressure Decrease Test Upstream Error =
FCT_ERROR in Pressure Decrease Test Upstream