DL06K Interim Tire-4 Diesel Engine Disassembly and Reassembly of Major Components
156
Fault code Fault content Occurrence conditions
57. Injection Misfire detection cylinder 2
P0305 DFC_MisfDetMisfireCyl_4_C Injection Misfire detection cylinder 2
58. Injection Misfire detection cylinder 4
P0306 DFC_MisfDetMisfireCyl_5_C Injection Misfire detection cylinder 4
59. Monitoring Misfire detection multiple cylinder
P0300 DFC_MisfDetMisfireMul_C Monitoring Misfire detection multiple cylinder
60. Monitoring of ADC
P060B DFC_MoCADCNTP NTP error in ADC monitoring
P060B DFC_MoCADCTst ADC test error
P060B DFC_MoCADCVltgRatio error in Voltage ratio in ADC monitoring
61. Monitoring of communication module
P060C DFC_MoCComErrCnt errors in query-/response communication
P060C DFC_MoCComSPI errors in SPI-communication
62. Monitoring of complete ROM test
P060C DFC_MoCROMErrXPg
multiple error while checking the complete
ROM-memory
63. ECU shut off path error
P060C DFC_MoCSOPErrMMRespByte
Too less bytes received by MM from CPU as
response
P060C DFC_MoCSOPErrNoChk Error during SOP test
P060C DFC_MoCSOPErrRespTime Error trying to set MM Response time
P060C DFC_MoCSOPErrSPI Error detected in the SPI communication
P060C DFC_MoCSOPLoLi
Error in the check of the shut-off path test of the
under voltage detection
P060C DFC_MoCSOPMM
Error in the check of the shut-off path of the
monitoring module
P060C DFC_MoCSOPOSTimeOut
Time out error trying to set or cancelling the
alarm task
P060C DFC_MoCSOPPsvTstErr Error during positive test
P060C DFC_MoCSOPTimeOut Error in time monitoring of the shut-off path test
P060C DFC_MoCSOPUpLi
Error in the check of the shut-off path test of the
over voltage detection
P1008 DFC_EngICO
Shut-off request of the injection cut-off for the
shut-off coordinator in case of a standard ICO
64. Monitoring of overrun
P101A DFC_MoFOvR Monitoring of overrun error
65. Monitoring of voltage supply
P1600 DFC_MonUMaxSupply1 Reported Over Voltage of Supply
P1601 DFC_MonUMinSupply1 Reported Under Voltage of Supply
66. ECU main relay
P068A DFC_MRlyErlyOpng Early opening defect of main relay
P068B DFC_MRlyStk stuck main relay error
67. DPF Pressure sensor hose line check
P2453 DFC_NplHsChngPPFltDiff
the monitoring for incorrectly connected hose
lines of the differential pressure sensor