DL06K Interim Tire-4 Diesel Engine Disassembly and Reassembly of Major Components
70
b) Distortion of lower surface
z As shown in figure, measure the
cylinder head’s distortion at 6
directions with horizontal ruler and
clearance gauge.
z If the measured value is beyond the
limit value, correct it by means of the
fine grinding paper or grinding
machine.
z If it is beyond the max. allowable
value, replace the cylinder head.
< Lower face warpage and height >
(mm)
Dimension
Description
Standard Limit
Warpage
0.08
or less
0.15
Thickness : t
(reference)
104.9 ~
105.1
104.4
c) Flatness
z Check the flatness of the installing surface of cylinder head's intake and exhaust
manifolds with horizontal ruler and clearance gauge.
(mm)
Standard Limit
0.15 0.3
d) The hydraulic test
z The hydraulic test of cylinder head is same as the cylinder block test.
(t)