4. Regular inspection
43
Use of Genuine Parts
An engine consists of many parts which are mechanically
harmonized. To prevent engine faults in advance and use
engines with best performance for a long period, mainte-
nance and replacement of expendable parts should be
conducted regularly.
Use of genuine parts is recommended. Using unauthorized
or remanufactured parts may cause critical damage and
faults to engine for which Doosan shall not be held liable.
Drain Fuel filter / Water separator
Check of fuel stop lever
Engine Clean fuel pre-filter
Replace Fuel filter
Replace Water separator filter
Drain Water & Sediment from fuel
tank
Check of Injectors, replace if neces-
sary
a
Replace Fuel Hoses, Clamps
Electrical System
Engine alarms
Check of battery charging
Magnetic pick up and adjust
Cylinder Head
Cylinder head valve and valve seats
Check of valve clearance
Every
1,000 hrs
a. If the sulfur content of fuel is > 0.02wt%, the changer or check intervals should be halved.
Check Points Daily
Inspection interval (Hours)
Remark
First
50
200 400 500 800 1,600 3,200 1Year 2Year