13SafeRoute® System 2019-03WN 059722 45532
dormakaba System manual Annex
12 Annex
SLI
Mini
SLI
Basic
SLI
Standard
Release Via emergency button (with alarm trigger) ○ ○ ○
Unlock Via key switch(without alarm trigger)
– Temporary unlocking ○ ○ ●
– Long-term unlocking - - ●
– Permanent unlocking ○ ○ ○
– Operating time of the key switch for triggering the
unlocking type long-term permanent unlocking
- - ●
– Combination function short-term, long-term, permanent
unlocking: one of the different unlocking types can be deactivated
- - ●
Automatic unlocking at defined times of day (timer) - - ●
By alarm system (fire, danger, smoke detectors, sprinklers, etc.) ○ ○ ○
Bi-directional escape route - ○ ○
From outside to inside via external analog ST (key switch) ○ ● ●
From outside to inside via external DCW® ST or SVP / M-SVP xx - ● ●
Lock Automatic relocking
– After temporary unlocking ○ ○ ●
– After long-term unlocking - - ●
– If door was not opened after pressing the emergency button
1)
- ● ●
– After closing - - ●
Automatic locking at defined times of day (timer) - - ●
Automatic relocking after power cut ○ ○ ○
Resetting the unlocking via key/emergency button ○ ● ●
Direct connection of motor locks
SVP 2xxx DCW®/ M-SVP 22xx DCW®
- ● ●
Vis./Aud. display Status/Warning/Initialization display on the illuminated ring.
– Adjusting the brightness - ● ●
– Adjusting the flashing frequencies - - ●
Pre-alarm/main alarm after temporary unlocking and
long-term unlocking
○ ○ ●
Maintenance alarm ○ ○ ●
Acoustic confirmation when activating
long-term or permanent unlocking
○ ○ ●
Alarm duration limit ○ ● ●
Alarm management (activation/deactivation of alarms) - ● ●
Monitoring Tamper monitoring (can be deactivated for maintenance purposes) ● ● ●
“Door open” monitoring ○ ○ ●
Two different time ranges for
the “door open” monitoring’s pre-alarm and main alarm
- - ●
Entry control Access control via keypad, e.g. STD-UP touchscreen display - - ●
History memory with date and time stamp - - ○
Networking LON - ● ●
LAN - ○ ○
Miscellaneous Automatic reactivation after power cut ○ ○ ○
Parameterization/visualization/control via TMS Soft® - ● ●
Freely programmable inputs/outputs on the SCU - ● ●
Additional programmable inputs/outputs via SIO-DR or I/O DCW® - - ●
Application cards
SLI-A
Multi-door control - ■ ■
Interlock control - ■ ■
Logic functions - - ■
Time-Delayed Release
1)
- ■ ■
– one time delay step (parameterizable) - ■ ■
- not available ○ available, not parameterizable ● available and parameterizable ■ with app
1)
EN 13637 function