13SafeRoute® System 2019-03WN 059722 45532
dormakaba System manual Annex
12 Annex
SLI
Mini
SLI
Basic
SLI
Standard
Release Via emergency button (with alarm trigger)
Unlock Via key switch(without alarm trigger)
– Temporary unlocking
– Long-term unlocking - -
– Permanent unlocking
Operating time of the key switch for triggering the
unlocking type long-term permanent unlocking
- -
Combination function short-term, long-term, permanent
unlocking: one of the different unlocking types can be deactivated
- -
Automatic unlocking at defined times of day (timer) - -
By alarm system (fire, danger, smoke detectors, sprinklers, etc.)
Bi-directional escape route -
From outside to inside via external analog ST (key switch)
From outside to inside via external DCW® ST or SVP / M-SVP xx -
Lock Automatic relocking
– After temporary unlocking
– After long-term unlocking - -
If door was not opened after pressing the emergency button
1)
-
– After closing - -
Automatic locking at defined times of day (timer) - -
Automatic relocking after power cut
Resetting the unlocking via key/emergency button
Direct connection of motor locks
SVP 2xxx DCW®/ M-SVP 22xx DCW®
-
Vis./Aud. display Status/Warning/Initialization display on the illuminated ring.
– Adjusting the brightness -
– Adjusting the flashing frequencies - -
Pre-alarm/main alarm after temporary unlocking and
long-term unlocking
Maintenance alarm
Acoustic confirmation when activating
long-term or permanent unlocking
Alarm duration limit
Alarm management (activation/deactivation of alarms) -
Monitoring Tamper monitoring (can be deactivated for maintenance purposes)
“Door open” monitoring
Two different time ranges for
the “door open” monitoring’s pre-alarm and main alarm
- -
Entry control Access control via keypad, e.g. STD-UP touchscreen display - -
History memory with date and time stamp - -
Networking LON -
LAN -
Miscellaneous Automatic reactivation after power cut
Parameterization/visualization/control via TMS Soft® -
Freely programmable inputs/outputs on the SCU -
Additional programmable inputs/outputs via SIO-DR or I/O DCW® - -
Application cards
SLI-A
Multi-door control -
Interlock control -
Logic functions - -
Time-Delayed Release
1)
-
– one time delay step (parameterizable) -
- not available available, not parameterizable available and parameterizable ■ with app
1)
EN 13637 function