D14 MZ 3000
D14 TMZ 3000
D14 MZ 2
D14 TMZ 2
D14 MZ 5
D14 TMZ 5
D 14 MZ 10
D 14 MZ 520
owner’s manual
manual de utilización
manuel d’utilisation
14 GPM

Questions and Answers

  • S
    Sabrina BoltonAug 4, 2025
    How to fix a damaged motor piston in dosatron D14 MZ 3000 Laboratory Equipment?
    • A
      Amy SmithAug 4, 2025
      If the motor piston in your DOSATRON Laboratory Equipment is damaged, contaminated, or the check valve parts are worn or missing, you should return the unit to your service center for repair or clean/replace the affected parts.
  • H
    Henry HarrisAug 12, 2025
    What to do if dosatron D14 MZ 3000 has a blocked suction tube?
    • R
      Richard MartinezAug 12, 2025
      If your DOSATRON Laboratory Equipment isn't drawing concentrate and you suspect a blocked suction tube or clogged strainer, clean or replace the affected component.
  • S
    sonyabowmanAug 19, 2025
    What to do if motor piston dosatron D14 MZ 3000 Laboratory Equipment does not start?
    • P
      Peter DiazAug 19, 2025
      If the motor piston in your DOSATRON Laboratory Equipment doesn't start, or you notice injection water flowing back into the concentrate container, here's what you can check: * **Piston Stalled:** Try resetting the piston by hand. * **Air in the Unit:** Bleed air from the unit using the bleed button. * **Maximum Flow Exceeded:** 1. Reduce the flow and restart the unit. 2. Unscrew the bell, remove the piston, and inspect the piston valve seals to ensure they are correctly positioned. * **Damaged Motor Piston:** If the motor piston is damaged, contaminated, or the check valve parts are worn or missing, return the unit to your service center for repair, or clean/replace the affected parts.
  • B
    Barbara MartinAug 27, 2025
    Why is there no suction of concentrate in my dosatron D14 MZ 3000?
    • D
      dennismargaretAug 27, 2025
      If your DOSATRON Laboratory Equipment is not drawing concentrate, consider these potential causes and solutions: * **Piston Motor Stopped:** Refer to the Motor Piston section for troubleshooting. * **Air Leak (Inlet):** Check the tightness between the nut and suction hose to eliminate any air leaks. * **Blocked Suction Tube or Clogged Strainer:** Clean or replace the suction tube or strainer if they are blocked. * **Missing or Worn Components:** Clean or replace the suction check valve seal or plunger seal if they are missing or worn. * **Worn Injection Stem:** Replace the injection stem if it is worn.

Summary

Quick start-up

Specifications

Adjusting the Injecting Rate

Installation

Precautions

General safety and operational guidelines for installing the Dosatron unit, covering common risks and best practices.

Assembling the Dosatron

Step-by-step instructions for physically assembling the Dosatron unit and its mounting bracket.

Putting the DOSATRON into order

Using for the First Time

A step-by-step guide for the initial setup, priming, and first-time operation of the Dosatron.

Maintenance

Fitting the Suction Tube

Adjusting the Injection Rate

Changing the Motor Piston

Changing Seals in the Injection Assembly

Changing the Dosing Seals

Cleaning and Re-assembling the Suction Valve Seal

Troubleshooting

Leaks

Guides users through diagnosing and fixing various types of leaks occurring in the Dosatron unit.

Limited Warranty

Parts Diagram

D14 MZ2 - Parts Diagram

D14 MZ5 - Parts Diagram

D14 MZ10 - Parts Diagram

D14 MZ520 - Parts Diagram

dosatron D14 MZ 3000 Specifications

General IconGeneral
ModelD14 MZ 3000
CategoryLaboratory Equipment
Injection TypeProportional
Flow Rate3000 L/h
Maximum Flow Rate3, 000 L/h
Dosing Range0.03% to 0.3%
Pressure Range0.3 to 6 bar
Operating Pressure0.3 to 6 bar
Pressure0.3 to 6 bar
Temperature Range5°C to 40°C
MaterialsPolypropylene, EPDM
MaterialPolypropylene, EPDM
Connection Size3/4" NPT
Power SupplyHydraulic
Dimensions150 mm