Revision1.2ROMIII“‐L”&“‐LIQ”Installation&OperationManualPageNo.5of15
2.  General Specifications 
 
Parameter  Minimum   
Maximum  Units 
Input Voltage  9  30  VDC 
Input Current    1  A 
Ambient Operating Range  -40°  +70°  Celsius 
Storage Temperature  -40°  +70°  Celsius 
Max. Surface Temperature    +135°  Celsius 
NON I.S. Relay (TB1) Voltage    30  V 
NON I.S. (TB1) Relay Current    5  A 
I.S Aux Out (TB4) Voltage    20  V 
I.S Aux Out (TB4) Current    50  mA 
Altitude  2000 M 
Humidity  100%  
 
The ROM III is rated for outdoor use having an overvoltage category code I and pollution 
degree 2 according to UL 61010-1 standard. 
 
3.  Intrinsic Safe Specifications 
 
This section is agency controlled, hence shall not be changed without permission of agency. 
 
The ROM III has been assessed by compliance with the following documents: 
 
EN IEC 60079-0: 2018    EN 60079-11: 2012    EN 60079-15: 2010 
 
Equipment Label Marking: 
 
 
 
 
 
 
 
 
 
 
Description of Equipment or Protective System: 
 
General - The ROM III is a tank truck / trailer mounted On Board Monitoring (OBM) system 
providing intrinsically safe connections for sensors mounted in the top and bottom of each 
tank compartment. 
The ROM III monitor detects and communicates the sensor status and 
overall unit’s “permissive to load” (the tanker) status to a loading rack monitor via its socket 
outputs.  The ROM III is powered by connection to the truck battery.  The Model #1910A ROM 
Terminator is used to terminate the unused sensor input circuits
.