EasyManua.ls Logo

Dräger LFB PSS 7000 - Technical Data

Dräger LFB PSS 7000
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
476 Issue date: 17 November 2006 57 of 80
24 Technical data
PSS 7000 BA set
24.1 The Dräger PSS
®
7000 series conforms to EN 137: 2006 and to the requirements of the EC
Council Directive 89/686/EEC. BSEN 133.
24.2 The equipment is CE mark approved and is issued with an EC type examination certificate.
24.3 ATEX certification (94/9/EC) For specific combinations of the PSS
®
7000 Series of SCBA, the
approved groups/classes are defined as follows:
0359 I 1M/II 1GD ITS 07 ATEX 25580 Ex ia I/IIC T4 (Ta-30°C
to+60°C).
24.4 Weight of BA set with battery pack, FPS face mask and LDV plus BA personal line attached but
without cylinder SDBA = 6.45 kg. EDBA = 7.05 kg.
24.5 Weight of BA set with battery pack, FPS face mask and LDV, BA personal line attached, fully
charged cylinder with cover fitted is approximately SDBA = 15.50 kg. EDBA = 22.15 kg.
Conformity
24.6 The Dräger PSS® 7000 Series conforms to EN137 and to the requirements of EC Council
directive 89/686/EEC, BSEN 133. The equipment is CE mark approved and is issued with an EC
type examination certificate.
24.7 ATEX certification (94/9/EC) for specific combinations of the PSS7000 Series (the approved
groups/classes) is defined as follows: CE I M1/II 1 GD IIC T6 (Ta -30°C to +60°C).
Reducer
24.8 The main body of the reducer is manufactured from brass to specification BSEN 12420 - CW
617N. The pressing is precision machined and then externally Nickel plated.
24.9 The thread of the standard hand wheel, fitted to the reducer, is to DIN G5/8 as per EN 144-2:
1999.
24.10 The inlet to the reducer has a threaded hand wheel for connection to the high pressure outlet
port of the valve of a compressed air 300 bar cylinder.
24.11 Normal first stage output pressure 8 bar.
24.12 First stage output flow (l/min) > 1000.
24.13 High pressure pneumatic whistle activation pressure (bar) 74 (+/- 5 bar).
24.14 Whistle sound level (dBA) > 90.
24.15 Whistle frequency range (Hz) 2000 4000.
Threaded hand wheel: (300bar)
24.16 The thread of the standard hand wheel is to DIN G5/8 as per EN 144: 2000.
Cylinder SDBA
24.17 Dräger 8 litre 300 bar carbon composite cylinder (30 year design life).
24.18 Charging pressure 300 bar.

Related product manuals