476 Issue date: 17 November 2006 13 of 80
temperature to stabilise and
then charge.
Was fully charged but now battery
drained.
Check BA set is shut down
correctly and the air is
purged. Remove charger and
refit. If the problem persists
contact OSG.
Charging (fast) low capacity.
Fault, Battery low capacity or battery
temp may be too high or too low.
Remove from charge. Leave
approximately 30 minutes for
temperature to stabilise and
then charge.
7 FPS 7000 dual purpose face mask
Face mask identifying features