English
9
Cleaningtheinsideofchemicaltank
3.Cleaning,Recharging,andStorage
–Afterrecoveringtheremnantsolution,cleantheinsideofchemicaltankbyusingcleanwater.
k
Beforecleaning,inspectionandrecharging,makesureunitisturnedoff.
CAUTION
Cleaningthepumpinsidewithwater
CAUTION
After cleaning the inside of chemical tank, pour water into the tank again, run the pump, and clean the
pump inside and the nozzles until the sprayed mist of chemical solution is completely replaced with
clean water.
Leaving the pump inside without it being water-cleaned will cause failure of the pump and nozzles.
Cleaningthestrainer
–Cleanthestrainer.
Waterdraining
–Donotfailtodrainthetank.Otherwisethefreezingofwatermaydamagethepumpinwinter.
–Afterdrainingthechemicaltank,gripthegriplevertorunthepumpwithoutloadasfarastheremaining
waterinthetankiscompletelydischarged.Nevercontinuetheno-loadrunofthepumpforlongerthan1
minute.Otherwisethepumpmaybedamaged.
CAUTION
Methodforusingthemeasuringcup
Themeasuringcupis onthebacksideofthe
chemicaltanklid.(Themeasuringcupis
detachablefromthechemicaltanklid.)
Tokeepthesolutionfromcontamination,be
sure to dissolve the chemical in another
containerandfilterthesolutionwiththestrainer
beforepouringitintothechemicaltank.
Howtoremovethestrainer
Setthe ribsontheboth sideoftheinner strainer
horizontalorverticaltothechemicaltankto
removethestrainer.
Withtheribsonthebothsidesoftheinnerstrainer
horizontalorverticaltothechemicaltank,turnthe
ribsby45degrees to semifix the strainer to the
chemicaltank.Doingsopreventsthestrainerfrom
risingwhenusingfoamingchemicals.
100X
200X
500X
Figures in the chart are rough estimate for the dilution
strength.
150
75
30
50X 300 (mL)
Use the gauge for 15 liters.
ribs
strainer