EasyManua.ls Logo

Dreamline FRENCH LINEA Series User Manual

Dreamline FRENCH LINEA Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© DreamLine
®
All Rights Reserved
© DreamLine
®
All Rights Reserved
PLEASE REVIEW THIS ENTIRE MANUAL PRIOR TO INSTALLATION
1-866-731-2244
FRENCH LINEA
SHOWER PANEL INSTALLATION INSTRUCTIONS
Do Not Return Product to the Store. Contact DreamLine® with any questions
IMPORTANT!
DreamLine
®
reserves the right to alter, modify or redesign products at any time without prior notice for the
purpose of product improvement and customer experience. Please refer to the model’s web page on
DreamLine.com for the latest technical drawings, installation manuals, warranty information or additional
product details.
FRENCH LINEA Shower Panel Installation Manual Ver 2 022020
©2020 DreamLine® All Rights Reserved.
MAZE
D3234720HX-09
BLOSSOM
D3234720ZNB-09
RHONE
SHDR-3234721-87
AVIGNON
SHDR-3234721-86
OMBRE
D3234720PXB-01 (chrome)
D3234720PXB-09 (satin black)
TOULON
SHDR-3234721-89
right wall installation shown

Questions and Answers:

Dreamline FRENCH LINEA Series Specifications

General IconGeneral
BrandDreamline
ModelFRENCH LINEA Series
CategoryBathroom Fixtures
LanguageEnglish

Summary

ClearMax Coating Information

General Preparation

Package Inspection and Surface Preparation

Inspect packages, ensure surfaces are level and solid, and protect during installation.

Code Compliance and Safety Precautions

Adhere to codes, use licensed plumbers, and follow all safety warnings for injury prevention.

Tempered Glass Safety Warnings

Glass Breakage Causes and Prevention

Understand glass breakage causes (handling, misuse) and follow safety precautions to prevent injury.

Model Specific Preparation

Alignment, Leveling, and Reversibility

Adjust for out-of-plumb walls, ensure threshold is level, and note the model's reversible design.

Installation Requirements and Recommendations

Consult manufacturers for drilling, and professional installation by two is recommended.

Tools and Preparation Notes

Essential Tools List

Lists all necessary tools for the installation process.

Pre-Installation Checks and Part Inspection

Verify size, measure opening, inspect parts, protect drain, and set screw gun clutch.

Shower Panel Components Diagram

Parts List

Hardware and Glass Component Details

Detailed list of hardware and glass components, including part numbers and quantities for reference.

Strike Vinyl Usage Note

Clarifies that 180° Strike Vinyl is used only for door and inline panel configurations.

Model Diagrams and Dimensions

Single Panel Installation Details

Provides dimensions and recommended opening size for the 34"x72" single panel installation.

Inline Panel Installation Guidance

Specifies minimum space for inline panels and advises installing the shower door first.

Installation Step 1: U-Channel Alignment

Vertical U-Channel Adjustment

Verify walls and threshold level for up to 1/2" out-of-plumb adjustment.

Installation Step 2: Glass Measurement

Measure Glass Dimensions

Measure and record the glass width (W) and height (H) for installation.

Patterned Glass Orientation

Patterned glass should be installed with the wider border at the bottom.

Installation Step 3: Cutting U-Channels

Cutting Bottom U-Channel

Cut the Bottom U-Channel to the specified dimension, considering wall out-of-plumb.

Cutting Vertical U-Channel

Cut the Vertical U-Channel to the specified height for the 72" model.

Installation Step 4: Marking and Alignment

Marking Bottom U-Channel

Mark at least three (3) holes for securing the Bottom U-Channel to the threshold.

Aligning Inline Panel Glass

Align inline panel glass parallel to the door, place U-channel, and mark the threshold.

Installation Step 5: Securing U-Channels

Securing to Acrylic Threshold

Drill Ø1/8" holes and use screws for installation into an acrylic threshold.

Securing to Tile Threshold

Drill appropriate holes into studs for installation into a tile threshold.

Installation Step 6: Countersinking Screws

Glass Protection via Countersinking

Ensure screws are fully countersunk to prevent damage to the glass.

Installation Step 7: PVC Glass Spacers

Cutting PVC Glass Spacers

Cut several 2"-3" pieces of the PVC Glass Spacer 0.5mm.

Installing PVC Glass Spacers

Install cut PVC Glass Spacer pieces into the Bottom U-Channel, not one continuous piece.

Installation Step 8: Strike Vinyl Placement

Strike Vinyl Orientation and Notching

Determine strike vinyl orientation and cut a 1" notch for a tight fit around the Bottom U-Channel.

Installation Step 9: Panel Insertion

Vertical U-Channel Placement

Place the Vertical U-Channel on top of the Bottom U-Channel for the installation.

Panel Glass Insertion

Insert the panel glass into the vertical and bottom U-channels as shown.

Installation Step 10: Panel Alignment and Adjustment

Dry-Fitting Single Panel Glass

Optionally dry-fit the Panel Glass into the U-channels before marking the Vertical U-Channel position.

Inline Panel Alignment and Sealing

Align panel glass for a good seal with the door glass before marking the Vertical U-Channel.

Adjusting Panel Level with Spacers

Use PVC Glass Spacers to level panel glass with the door, not exceeding 1/4" adjustment.

Installation Step 11: Wall Mounting Holes

Drilling for Studded Walls

Drill into studs using appropriate bit sizes for secure mounting of the Vertical U-Channel.

Drilling for Non-Studded Walls

Drill holes and insert wall anchors for mounting the Vertical U-Channel when no stud is present.

Marking Vertical U-Channel Holes

Mark at least four (4) holes for accurately positioning the Vertical U-Channel on the wall.

Installation Step 12: Securing Vertical U-Channel

Securing Vertical U-Channel

Secure the Vertical U-Channel to the wall using screws, ensuring it sits atop the Bottom U-Channel.

Glass Protection during Securing

Ensure screws are fully countersunk to prevent damage to the glass.

Installation Step 13: Bottom U-Channel Spacers

Applying Silicone and Spacers

Apply silicone into the Bottom U-Channel, then install PVC Glass Spacers to protect the glass bottom edge.

Installation Step 14: Final Glass Insertion

Sliding Panel Glass into U-Channels

Slide the panel glass into the vertical U-channel first, then down into the bottom U-channel.

Installation Step 15: Silicone Curing

Final Silicone Application and Curing

Ensure surfaces are clean before applying silicone and allow 24 hours for it to cure before use.

Product Maintenance

Cleaning Guidelines

Clean acrylic surfaces with non-abrasive cleaners; wipe glass and hardware with soft cloths.

Inspection and Care

Regularly inspect glass and hardware for misalignment, proper attachment, and damage.

Maintenance Checklist

Perform regular checks on unit stability, u-channels, seals, glass edges, and silicone for upkeep.

Troubleshooting

Missing Parts

Check packaging for missing parts; contact Customer Support if not found to order replacements.

Door Alignment Issues

Inspect strike vinyl orientation and installation for flush door closure and panel alignment.

Leakage Beneath U-Channel

Ensure screws are secure and silicone application is complete and cured to prevent leaks.

Contacting Customer Service

Have purchase order, model number, and factory part information ready before contacting customer service.

Factory Parts Information - Hardware

Hardware Component Details

Provides a detailed list of hardware components, including part numbers and quantities for replacement.

Factory Parts Information - Glass Panels

Glass Panel Specifications

Details specific part numbers and sizes for the glass panels of each French Linea model.