Visit our website at: http://www.harborfreight.com
Email our technical support at: productsupport@harborfreight.com
Do not return this
pump to the store.
Call 1-844-416-9141
Owners Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions, assembly,
operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the
back of the manual near the assembly diagram (or month and year of purchase if product has no number).
Keep this manual and the receipt in a safe and dry place for future reference. 17d
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
Copyright
©
2017 by Harbor Freight Tools
®
. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and s er vi ce m ay n ot be i nc lu de d.
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.

Questions and Answers:

Drummond 63892 Specifications

General IconGeneral
BrandDrummond
Model63892
CategoryWater Pump
LanguageEnglish

Summary

Safety and Operation Guidelines

GFCI Protected Outlet Requirement

Ensures pump is connected only to a GFCI protected outlet to prevent electric shock.

Electric Shock and Usage Warnings

Highlights risks of electric shock, improper grounding, and unsuitable locations like pools.

Electrical Connection and Environmental Safety

Stresses protecting connections from moisture and flood conditions.

Operational and Fluid Handling Precautions

Advises against caustic fluids, frost, dry running, and child access.

Product Chemical Disclosure and Pacemaker Advisory

Informs about product chemicals and potential pacemaker interference.

Fluid Type and Temperature Limitations

Specifies the pump is for water only, up to 77°F, and not for fuels or chemicals.

Specifications and Requirements

Technical Specifications

Details electrical rating, amperage, cord length, flow, head lift, and discharge port size.

Installation Guidelines

Covers stationary installation methods and important notes on basin setup and maintenance.

Power Supply and Cord Safety

Addresses GFCI socket requirements, socket condition, and safety for damaged power cords.

Application Scope

Defines permitted uses like groundwater removal and water transfer, and prohibited uses like pools or septic systems.

Installation Instructions

Sump Basin Construction

Details the required dimensions for constructing a suitable sump basin.

Pump Positioning and Float Switch

Guides on placing the pump and ensuring the float switch movement is unobstructed.

Sump Cover and Cord Management

Explains fitting a sump cover with holes for output pipe and power cord.

Discharge Pipe and Check Valve Installation

Instructs on attaching discharge pipe, using PTFE tape, and installing a check valve.

Discharge Pipe Routing

Provides guidance on directing water discharge away from the foundation and pipe slope.

Operation and Maintenance

Pre-Operation Checks

Lists essential checks before starting the pump, including position, connections, and power.

Maintenance Safety Warning

Advises to unplug the pump before performing any inspection or maintenance.

Quarterly Maintenance Procedures

Details cleaning sludge/debris, checking leaks, ensuring check valve function, and testing flow switch.

Pump Disassembly and Cleaning

Step-by-step guide to dismantling the bottom part for cleaning the impeller and housing.

Troubleshooting Guide

Pump Not Delivering Water

Addresses issues like clogged inlet/impeller, low voltage, or faulty check valve.

Pump Won't Start or Run

Covers potential causes such as power connection issues, clogged parts, or motor defects.

Excessive Noise or Vibration

Identifies debris in the impeller as a primary cause for noise and vibration.

Pump Starts and Stops Frequently

Explains causes like high water temperature, stuck check valve, or backflow.

General Servicing Safety

Emphasizes following safety precautions and disconnecting power before servicing.

Parts List and Diagram

Component Parts List

Provides a list of all parts with their descriptions and quantities.

Assembly Diagram

Illustrates the pump assembly with numbered components corresponding to the parts list.

Warranty Information

Limited 90 Day Warranty

Outlines the warranty period, coverage, exclusions, and claim process.

Warranty Limitations and Exclusions

Details what is not covered by the warranty, such as misuse or lack of maintenance.

Legal Rights and Disclaimers

Explains consumer rights, limitations on incidental damages, and other applicable laws.