Page 4 For technical questions, please call 1-888-866-5797. Item 63477
Installation Instructions
1. Attach one end of a discharge hose to the
discharge port. Place the other end as needed
to direct the water discharge at least 3 feet
away from the source. Slope the discharge
hose downward, away from the source.
2. Place Pump in water.
DANGER! Do not use an extension cord with this Pump.
Keep plug dry and secured away from water.
3. Plug Power Cord into GFCI protected
outlet to start the Pump.
Operation
After reading these instructions, consider the following points before starting the Pump:
1. Verify that the Pump rests on the floor of the basin,
if it is not suspended by the handle.
2. Verify that the discharge pipe is properly connected.
3. Verify that the electrical connection
is 120 VAC, 60 Hz.
4. Verify that the electrical socket is GFCI
protected and in good condition. Test
GFCI protected outlet before use.
5. Verify that water and moisture cannot
get near the power supply socket.
6. Verify that the Pump is installed so
as to prevent running dry.
NOTE: The Pump will not start without 2-1/4" of water.
GFCI-
Protected
Receptacle
Discharge
Hose
Power
Cord