EasyManua.ls Logo

DSC Envoy NT9010 - Page 32

DSC Envoy NT9010
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2: Advanced Programming
28
NOTE: To change the volume of the voice prompts from the NT9010 unit you
must use the Volume Key on the NT9010.
[*] [8] Flash Programming / Advanced Programming
Enter [][8] followed by the Installer Code to enter Flash Programming, or the Advanced
Programming sections (see Section 2.1: Programming the NT9010 on page 15).
[*] [9] Arming Without Entry Delay
When a system is armed with the [][9] command the system will remove the entry delay
from the system. After the exit delay, Delay 1 and Delay 2 type zones will be instant and
Stay/Away zones will remain bypassed. (see 2.3.1 Zone Definitions on page 33). When
the system is armed in this mode, the Armed light will be flashing and NT9010 will
announce that there are zones bypassed.
For more information regarding this feature, see the NT9010 User’s Guide.
[*] [0] Quick Arm
If the Quick Arm Enable option is on, the system can be armed by entering [][0]. This is
a useful method of arming the system when someone doesn’t have an access code.
NOTE:The Quick Arm feature must be enabled in order for the Stay/Away func-
tion keys to operate as intended. If the feature is not enabled, the user will be
required to enter a valid access code after pressing the Stay or Away function
key in order to arm the system in the stay or away mode.
[*] [0] Quick Exit
Quick Exit will allow someone to leave an armed premise through a Delay type zone with-
out having to disarm and rearm the system.
When [][0] is entered, if the Quick Exit Enabled option is on, the system will provide a
two minute window to exit. During this time the system will ignore the first activation of a
Delay type zone. When the Delay zone is secured the system will end the two minute time
period.
If a second Delay zone is tripped, or if the zone is not restored after two minutes, the sys-
tem will start entry delay.
Quick Arm Enable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [015], Option [4]
Quick Exit Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [015], Option [3]
2.2.10Function Keys There are eight function keys on the NT9010 labelled Stay, Away, Chime, Exit, Status, Vol-
ume, Record and Playback. The operation of these keys is described below. Users can acti-
vate each function by pressing the key.
The programming of any function key on the NT9010 may be changed to any of the
options listed below. To change the programming of a function key:
1. Enter [][8][Installer’s Code].
2. Enter section [807].
3. Enter [000] for function key programming.
4. Enter the 2-digit code for the function you want to program for each key. (Each
function is described below.)
5. When you are finished, press [#] to exit.

Table of Contents

Other manuals for DSC Envoy NT9010

Related product manuals