PowerSeries Neo Installation Guide
Access Codes
l Up to 1002 access codes: 1000 (level 2-EN), one installer code
(level 3-EN), and one maintenance code
l Programmable attributes for each user code
l When using 8-digit access codes, the minimum number of vari-
ations are:
HS2016: 2083333
HS2032: 1388888
HS2064/HS2128: 1052631
HS2064 E: 200000
HS2128 E: 100000
Warning Device Output
l Integral sounder capable of 85 dB @ 3m, self-powered type Z
l 2 remote, wireless indoor/outdoor warning devices supported:
models PGX901 (indoor), PGX911 (outdoor) (X=4, 8, or 9)
l Programmable as steady, pulsed or temporal three (as per
ISO8201) and temporal four (CO alarm) output
l Warning device sounds alarms in the following priority: fire, CO,
burg
Memory
l CMOS EEPROM memory
l Retains programming and system status on AC or battery failure
for 20 years min.
Power Supply - International
l Input ratings: 220V-240Vac, 50/60Hz, 200mA
l Transformer required, mounted in the same enclosure,
permanently connected
l Transformer secondary ratings: 16.5Vac, 40VA min.
Note: For installations using the transformer mounted inside the cabinet,
replace fuse only with the same type (20mm) rated 250V/315mA.
Regulated power supply:
l 1.7A regulated, supervised and integral to the control unit
l Type A as per EN50131-6 Standard
l 700mA auxiliary supply, 12V DC
l Positive temperature coefficient (PTC) for Bell, Aux+ and Battery
terminals
l Reverse battery detection/protection
l Supervision for AC power and low battery
l Normal and high current battery charge options
l Supervised battery charging circuit
Current draw (panel):
l 85mA (nominal) 2A(Max)
Bell Output:
l 12V, 700mA supervised (1k Ohm) bell output (current limited at
2 amps)
l Steady, Pulsed, Temporal 3 fire, Temporal 4 CO alarm cadences
l Bell short detection (software + hardware)
Aux+:
l Voltage range = 9.6V - 13.8V DC
l Current = 700mA (shared with Corbus R(ed))
l Output ripple voltage: 270mVp-p max.
l Onboard programmable outputs:
l PGM 1 - 50mA switched programmable output
l PGM 2 - 300mA current-limited switched programmable
output. 2-Wire smoke detectors (90mA current limited)
are supported using this PGM
l PGM 3 - 50mA switched programmable output
l PGM 4 - 50mA switched programmable output
l Hardware PGM over current protection
Battery
l 12V sealed lead acid, rechargeable
l Battery capacity:
l 12 hours (EN50131),
l 24 hours INCERT [Belgium]
Note: For T 014 compliance (INCERT certification), only 14Ah
(2x7Ah) batteries were tested and are accepted for INCERT
certified systems.
l Maximum standby time: 24 hours (with 14Ah battery and Aux
current limited to 470mA)
l Recharging time to 80% 72 hours
l Recharging rate: 240mA (12 hours max.), 480mA (24 hour
backup)
l Backup time: 24 hours
l Battery lifespan: 3-5 years
l Low battery trouble indication threshold 11.5VDC
l Battery restore voltage 12.5V
l Main board current draw (battery only):
l HS2016/32/64/128 (no alternate communicator) standby
85mA DC
l HS2016/32/64/128, (including alternate communicator)
standby 190mA DC
l Transmit (alternate communicator module) 195mA DC
l Resettable fuses (PTC) used on circuit board
l Supervision for loss of primary power source (AC fail), battery
loss or battery low voltage (battery trouble) with indication
provided on the keypad
l Internal clock locked to AC power frequency
Operating Environmental Conditions
l Temperature range: EN= -10°C to 55°C (50°F-131°F)
l Relative humidity: <93% non condensing
Alarm Transmitter Equipment (ATE) Specification
l Digital dialer integral to the main control board
l Supports SIA and Contact ID
l Complies with TS203 021-1, -2, -3 Telecom equipment require-
ments and EN50136-1-1, EN50136-2-1, EN50136-2-3 ATS 2
l Optional Dual IP/Cellular communicators (3G2080(R)/ TL2803G
(R)/ TL280(R)) can be installed in the same enclosure and con-
figured as primary or back-up, with AES 128-bit encryption
l Compliant with EN50136-1-1, EN50136-2-1 ATS2 requirements
System Supervision Features
The PowerSeries Neo continuously monitors a number of possible trouble
conditions and provides audible and visual indication at the keypad.
Trouble conditions include:
l AC power failure
l Zone trouble
l Fire trouble
l Telephone line trouble
l Communicator trouble
l Low battery condition
l RF jam
l AUX power supply fault
l Failure to communicate
l Module fault (supervisory or tamper)
Additional Features
l 2-way wireless device support
l Visual verification (images + audio)