HS2016/2032/2064/2128 Alarm Panel
V1.0 User Manual
WARNING: This manual contains information on limitations regarding
product use and function and information on the limitations as to liability
of the manufacturer. The entire manual should be carefully read.

Table of Contents

Other manuals for DSC HS2016

Questions and Answers

  • D
    Donald EllisSep 9, 2025
    What does 'RF Delinquency' mean on my DSC Control Panel?
    • D
      David JacksonSep 9, 2025
      If your DSC Control Panel displays 'RF Delinquency', it means the HSM2HOST has not received a supervisory signal from a wireless device for 20 minutes. To resolve this, open/close the device, press a key on the keypad, or tamper/restore the device. Ensure the device is physically present and check for any device faults, like a low battery. Check the current signal strength and the signal strength during the last 24 hours. Try replacing the battery or the device itself.
  • D
    Daniel BlackAug 23, 2025
    What causes 'Communications' error on DSC Control Panel and how to resolve it?
    • S
      Sean RobertsAug 23, 2025
      If your DSC Control Panel displays 'Communications' issues, measure the voltage across TIP and RING on the panel. The voltage should be approximately 50VDC when no phone is off-hook and approximately 5VDC when any phone is off-hook. Try wiring the incoming line directly to TIP and RING. If the trouble clears, inspect the wiring or the RJ-31 phone jack.
  • K
    Kelsey FisherAug 25, 2025
    What to do if my DSC Control Panel says 'Panel No Battery'?
    • C
      Christopher PerezAug 25, 2025
      If your DSC Control Panel shows 'Panel No Battery', verify that the battery is connected. Refer to the troubleshooting steps for a panel low battery.
  • A
    Amanda RobinsonAug 26, 2025
    What does 'HSM2300 Low Battery' mean on my DSC Control Panel and how can I fix it?
    • R
      Ronald MorenoAug 27, 2025
      If your DSC Control Panel displays 'HSM2300 Low Battery', enter 07 to view which HSM2300 has a battery voltage less than 11.5V. Charge the battery, as it may be low due to a long period without AC. If the battery is old and no longer able to hold a charge, replace it.
  • A
    adamcurtisAug 28, 2025
    What does 'HSM2204 Battery Trouble' mean on my DSC Control Panel, and how can I fix it?
    • C
      Craig ColeAug 28, 2025
      If your DSC Control Panel displays 'HSM2204 Battery Trouble', the HSM2204 battery voltage is less than 11.5VDC. To resolve this, charge the battery, as it may be low due to a long period without AC. If the battery is old and no longer able to hold a charge, replace it.
  • M
    Mr. Craig GuzmanAug 29, 2025
    How to set Time and Date on DSC Control Panel?
    • B
      Bradley DurhamAug 29, 2025
      To program the time and date on your DSC Control Panel: Enter [*][6][Master Code] then press [01]. Enter the time and date (24-hour clock) using the format HH:MM MM/DD/YY. For example, for 6:00 pm, June 29, 2010, enter: [18] [00] [06] [29] [10].
  • T
    Terri Jones DDSSep 17, 2025
    What does 'Aux Supply' mean on my DSC Control Panel and how to fix it?
    • H
      hunter31Sep 17, 2025
      If your DSC Control Panel displays 'Aux Supply', check for a short between Aux+ and Aux- or another system ground. Ensure the aux current draw has not exceeded the documented limits.
  • D
    Douglas BakerSep 22, 2025
    What to do if I have a Bell Circuit problem with my DSC Control Panel?
    • R
      Rita RobinsonSep 22, 2025
      To troubleshoot a bell circuit issue on your DSC Control Panel, disconnect the Bell-/+ leads and measure the resistance. An open circuit indicates a break in the wiring or a defective siren/bell. You can also jumper Bell+/- with a 1K resistor (Brown, Black, Red).
  • C
    Charles JohnsonSep 8, 2025
    What does 'Module Supervisory' mean on my DSC Control Panel, and how do I fix it?
    • M
      Melissa SanchezSep 8, 2025
      If your DSC Control Panel indicates 'Module Supervisory' trouble, it means there is no supervisory response from an enrolled module. Modules are immediately enrolled and supervised. If a module is removed, or if the keypad slot is changed, module supervision must be reset. View the event buffer to identify the specific module(s) in trouble. To reset module supervision: Enter programming section [902]. Select auto or manual enrollment. Enter programming section [903] to identify modules connected to the Corbus.
  • D
    Deanna EatonSep 4, 2025
    How to fix AC Troubles on my DSC Control Panel?
    • R
      Ryan MartinSep 5, 2025
      If your DSC Control Panel shows 'AC Troubles', verify that the voltage measured across the AC terminals is 16-18VAC. If it is not within this range, replace the transformer.

Summary

Quick Reference Guide

Keypad Arming and Disarming Procedures

Instructions on how to arm and disarm the security system using the keypad.

Zone Bypassing Procedures

Procedures for bypassing individual zones or groups to exclude them from arming.

About Your Security System

System Testing Procedures

Procedure for performing weekly system tests to ensure proper operation.

Securing the Premises

Arming the System with a Keypad

Instructions for arming the system using various keypad modes like Away, Stay, and Night.

Arming with a 2-way Wireless Key

How to arm the PowerSeries Neo system using a 2-way wireless key.

Arming with a Proximity Tag

Procedure for arming the system using a proximity tag.

Bypassing Zones and Groups

Steps to bypass individual zones or groups to exclude them from arming.

Arming Errors and Exit Faults

Troubleshooting common errors and fault conditions during arming.

Disarming the System

Methods for disarming the security system using keypad, wireless key, or proximity tag.

Emergency Keys and Alarms

Emergency Keys and Alarm Functions

Using dedicated keys for Fire, Medical, or Panic alarms and alerting the monitoring station.

Alarm Types and Auditory Signals

Description of different alarm sounds and their corresponding event priorities.

Fire Alarm Response Procedures

Steps to follow during a fire alarm, including silencing and contacting the central station.

Carbon Monoxide Alarm Handling

Information on CO alarms, their sounds, and immediate actions to take.

Intrusion Alarm Handling and Cancellation

Handling intrusion alarms, silencing, and contacting the central station.

Wireless Keys and Other Devices

2-way Wireless Key Operation

Instructions for arming/disarming and calling for help using 2-way wireless keys.

Managing Users

Types of User Access Codes

Explanation of different user access code types like Master, User, Supervisor, Duress.

Configuring User Functions

Managing Troubles

Trouble Indication and Silencing

Understanding system trouble indicators, beeps, and how to view trouble levels.

Trouble Condition Categories and Codes

Detailed list of trouble conditions, types, and notification codes for system issues.

Managing Partitions

Additional Features

Installer Warning

System Installation and Failure Risks

Information on potential system failures and the importance of proper installation.

Safety Instructions

General Safety Precautions and Servicing

Essential safety instructions for using and servicing the equipment.

Maintenance and Troubleshooting Guidelines

Guidelines for cleaning, maintenance, and basic troubleshooting.

Locating Detectors and Escape Plan

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm