Reporting Code Code Sent When...
Dialer
Direction*
Recommended
Contact ID
SIA Auto Rep
Codes**
Periodic Test periodic test transmission Other (6) A2 RP-000
Buffer Near Full printer not used or off-line for 1875 events Other (6) 23 JL-000
User System Test bell/communications test Other (6) A1 RX-000
Walk Test Enabled walk test mode entered Other (6) A7 TS-000
Walk Test Disabled walk test complete Other (6) A7 TE-000
DLS Lead In
DLS Call Back feature only: downloading
session start
Other (4) 11 RB-000
DLS Lead Out
DLS Call Back feature only: downloading
session complete
Other (4) 12 RS-000
Installer Lead In Installer code has been entered Other (4) 58 LB-000
Installer Lead Out Installer's programming complete Other (4) 58 LS-000
LINKS Test LINKS test transmission Other (6) A3 TX-000
PC6204 Battery Trouble/Rest. PC6204 battery is low/restored Other (3) 3A YT-000/YR-000
PC6204 AC Line Trouble/Rest. PC6204 AC is disconnected/restored Other (3) 3A AT-000/AR-000
PC6204 AUX Trouble/Rest. PC6204 aux voltage supply trouble/restored Other (3) 3A UT-000/UR-000
PC6820 Battery Trouble/Rest. PC6820 battery is low/restored Other (3) 3A YT-000/YR-000
PC6820 AC Line Trouble/Rest. PC6820 AC is disconnected/restored Other (3) 3A AT-000/AR-000
PC6820 AUX Trouble/Rest. PC6820 aux voltage supply trouble/restored Other (3) 3A UT-000/UR-000
PC6400 RS232 Trouble/Rest. PC6400 RS232 trouble/restored Other (3) 35 VT-000/VR-000
PC6442 Battery Trouble/Rest. PC6442 battery is low/restored Other (3) 3A YT-000/YR-000
PC6442 AC Line Trouble/Rest. PC6442 AC is disconnected/restored Other (3) 3A AT-000/AR-000
PC6442 AUX Trouble/Rest. PC6442 aux voltage supply trouble/restored Other (3) 3A UT-000/UR-000
PC6443 Battery Trouble/Rest. PC6443 battery is low/restored Other (3) 3A YT-000/YR-000
PC6443 AC Line Trouble/Rest. PC6443 AC is disconnected/restored Other (3) 3A AT-000/AR-000
PC6443 AUX Trouble/Rest. PC6443 aux voltage supply trouble/restored Other (3) 3A UT-000/UR-000
PC6442 RS232 Communications
Trouble/Rest.
PC6443 communications trouble/restored Other (3) 3A NC-000/NR-000
Police Code Alarm/Rest.
two zones on the same partition go into alarm
within the Police Code Time during any given
armed period (incl. 24Hr zones)
A/R (1) 39 BV-000/BR-000
Duress Alarm/Rest. Duress code entered/restored A/R (1) 21 HA-UUU/HH-UUU
* A/R = alarms/restorals; O/C = openings/closings
** PPP = partition number; UUU = user number (user 1000=999); ZZZ = zone number
Zone Definition Recommended
Contact ID*
SIA Auto Reporting Codes**
Zone
Alm/Rest.
Zone
Troub/Tam
Alm/Fault-
/Rest.
Zone Alm/Rest. Zone
Troub/Tam
Alm/Fault/Rest.
Standard Delay, Force Arm Delay,
Auxiliary Delay, Instant, Interior
(1) 3A (3) 83 BA-ZZZ/BH-ZZZ BT-ZZZ/BJ-ZZZ
Standard Fire, Auto Verify Fire (1) 1A (3) 73 FA-ZZZ/FH-ZZZ FT-ZZZ/FJ-ZZZ
Momentary Arm, Maintained Arm n/a (3) 83 n/a UT-ZZZ/UJ-ZZZ
Holdup (1) 22 (3) 83 HA-ZZZ/HH-ZZZ HT-ZZZ/HJ-ZZZ
24Hr Bell, 24Hr Bell/Buzzer, 24Hr
Buzzer
(1) AA-61 (3) 83 BA-ZZZ/BH-ZZZ BT-ZZZ/BJ-ZZZ
Auxiliary, 24Hr Auxiliary (1) 52 (3) 83 ZA-ZZZ/ZH-ZZZ ZT-ZZZ/ZJ-ZZZ
24Hr Medical (1) AA (3) 83 MA-ZZZ/MH-ZZZ MT-ZZZ/MJ-ZZZ
24Hr Seismic (1) 3A (3) 83 BA-ZZZ/BH-ZZZ BT-ZZZ/BJ-ZZZ
LINKS Supervisory (3) 53
(3) 8A
US-ZZZ/UH-ZZZ US-ZZZ/UR-ZZZ
LINKS Answer n/a n/a n/a n/a
Table 2:
Zone Reporting Codes