PowerSeries Neo Installation Guide
SIA Feature Programming
Section
Comments Range/Default Requirement
Exit Time
[005]>[001], option 3
Access to Entry and Exit delays and Bell Time Out for the system. Range:45- 255
seconds
Default: 60 sec.
Required
(programmable)
Exit Delay Restart
[018], option 7
Opening a Delay zone door after it has already been opened and closed during an exit delay restarts the
exit delay timer.
Default: Enabled Required
Auto Stay Arm on Un-vacated
Premises
[001]>[001]-[128] Zone type 05,
06,09
Function key: Forces the system to arm in Stay mode if the occupant does not exit the premises after
pressing the Away function key.
If no exit after full
arm
Default: Enabled
Required
Exit Time and Progress
Annunciation/Disable or Remote
Arming
[861]>[001]-[005], option 4
System times and audible exit beeps can be disabled when using the wireless key to stay arm the system.
When away arming, audible exit beeps can not be disabled.
Default: Enabled Allowed
Entry delay(s)
[005]>[001]-[008], options 1 and 2
Access to entry and exit delays and bell time out for the system
Note: Combined entry delay and communications delay (abort window) shall not exceed 60s.
Range: 30 sec. to 4
min.
Default: 30 sec.
Required
(programmable)
Abort Window for Non-Fire zones
[002]>[001]-[128], option 7 ON
Access to zone attributes, i.e., swinger shutdown, transmission delay and cross zone. May be disabled by
zone or zone type.
Default: Enabled Required
Abort Window Time - for Non-
Fire zones
[377]>[002], option 1
Access to the programmable delay before communicating alarms
Note: Combined entry delay and communications delay (abort window) shall not exceed 60 seconds.
Range: 00 - 45 sec.
Default: 30 sees
Required
(programmable)
Abort Annunciation An audible tone is generated when an alarm is aborted during the abort window. Hard-coded ON Required
Duress Feature
[*][5]> master code> user 2-95> 5>
2
When this feature is enabled, selected user codes send a duress reporting code to the central station when
used to perform any function on the system. Section [019], option [6] must be enabled.
Default: N Required
Cancel Window
[377]>[002], option 6
Access to the communications cancel window. Minimum duration must be 5 minutes. Range: 005-255
Default: 005
Cancel Annunciation
[308]>[001], option 8
Access to the reporting code for Alarm Canceled. A Cancel was
transmitted
Default: Enabled
Required
Cross Zoning
[042]>Selection 3, option 002
Enables cross zoning for entire system. Zones can be enabled for cross zoning via zone attribute option
8 in sections [002][101] - [128].
Programming
required
Default: Disabled
Required
Burglary Verification Timer
[005]>[000], option 3
Access to the programmable Cross Zone timer. Range: 000-255 sec.
Default: 60 seconds
Allowed
Swinger Shutdown for Alarms
[377]>[001], option 1
Access to the swinger shutdown limit for zone alarms
For all non-fire zones, shut down at 1 to 6 trips.
Default: 2 trips Required
(programmable)
Swinger Shutdown Enable
[002]>[001] - [128], option 6 ON
Access to swinger shutdown, transmission delay and cross zone attributes. Zone attribute option 6
(Swinger Shutdown enabled) is ON.
Non-police response
zones
Default: Enabled
Allowed
24-Hr. Auto-verified Fire
[001]>[001]-[128], Zone type 025
ON
Access to 24-Hr. Auto-verified Fire
Activates if Not restored within the specified time.
Must choose zone
type for application
Required
Call Waiting Cancel
[382], option 4 OFF
Access to the dialing sequence used to disable call waiting. Call waiting string can be programmed in
[304]
Depends on user
phone line
Default: Disabled
Required
System Test:
[*][6] Master Code, option 04
The system activates all keypad sounders, bells or sirens for 2 seconds and all keypad lights turn on.
Refer to user manual (part no. 29008365).
Walk Test Mode:
[*][8][Installer code][901]
This mode is used to test each zone on the system for proper functionality.
Walk Test Communications
[382], option 2
Enables communication of zone alarms while walk test is active. Default: Disabled
Walk Test Start/ End Reporting
Codes
[308][401], options 1 and 2
Access to the reporting codes for walk test start and end times.
- 27 -

Other manuals for DSC Neo Power Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo Power Series and is the answer not in the manual?

DSC Neo Power Series Specifications

General IconGeneral
BrandDSC
ModelNeo Power Series
CategorySecurity System
LanguageEnglish

Related product manuals