PowerSeries Neo Installation Guide
Installer-Defined Access Codes
001 – Installer Code:
002 – Master Code:
003 – Maintenance Code:
System Account Code
Aux Loading and Battery Selection
HS2128/HS2064/
HS2032/HS2016
Board current draw 85mA
UL Residential Burg
ULC Residential Burg
UL Commercial Burg UL Resi Fire
UL Home Health Care
ULC Resi Fire
ULC Com Burg
ULC Fire Monitoring EN50131
Grade 2/Class II
Max AUX (NSC) current
loading
0.7A 0.7A 0.5A 0.5A 0.5A
Max BELL (Alarm) current
loading
0.7A 0.7A 0.7A 0.7A (no local alarm
notification allowed, only
remote transmission to
SRC)
0.7A
UL/ULC Listed enclosure
PC500C
PC5003C
CMC-1
PC4050CAR
PC5003C PC5003C
PC4050CR
(red/transfomer mounted
inside)
PC5003C
Power UC1
Transformer requirements
16.5V/40VA (plug in
type)
PTC1640U (USA)
PTC1640CG (CAN)
FTC1637 (cUL listed)
16.5V/37VA (Hardwired
type, mounted inside the
enclosure or outside using
electrical box)
16.5V/40VA
(hardwired type,
mounted inside the
cabinet)
Battery Capacity requirements
7Ah 7Ah 14Ah (2 x 7Ah in
parallel)
14Ah (2 x 7Ah in
parallel)
7Ah
Standby Time
4 hours 4 hours 24 hours 24 hours 12 hours
Alarm time
4 minutes 15 minutes 4 min (UL resi fire)
5 min (Home Health
Care and ULC Resi
Fire)
5 minutes (Alarm
Transmission only)
N/A
Recharging current setting
400mA, 700mA 400mA, 700mA 400mA, 700mA 400mA, 700mA 400mA, 700mA
- 21 -