Page #6 background imageLoading...
Page #6 background image
DOOR
CHIME
FEATURE
The
door chime feature is used, while the panel is disarmed, to provide a tone from
the keypad each time a door or window is opened or closed. The doors and windows
which will provide this indication are programmed by your installer.
Enter[*]
[5], [Master Code],
[OJ
to
turn the door chime feature
ON
and
OFF.
When
the command is entered, the keypad will beep 3 times if the feature
is
being enabled
and will sound one beep if the feature is being disabled.
SPECIAL
FUNCTION
COMMAND
The PC1000 can be programmed at the time of installation
to
operate other devices
such as electric door strikes, door openers, electric lights, cameras, etc. by pressing
[*]
then [7]
on
the keypad. Your installer will instruct you on the use of this command.
AT-HOME ARMING
COMMAND
Entering[*],
[9] before the 4 digit arming code arms the panel with no entry delay
on
the entry zones, and bypasses the interior zones that have been programmed as
"home-away" zones. This command is used to arm the system if someone is
remaining
on
the premises.
KEYPAD ZONES
There are three zones which can be activated from the keypad. A fire alarm is
activated by pressing the [1] and [3] keys at the same time. The fire alarm sounds
the bell/siren
in
a pulsed mode. A transmission will be sent to the monitoring station
ONLY if it has been programmed to
do
so by the installer.
The PC1000 can be programmed at the time of installation to send a transmission to
the monitoring station
by
simultaneously pressing keys [4] and [6]. The installer will
provide instructions
on
its use when required.
The Police (or Panic) alarm is activated by pressing the
[*land[#]
keys at the same
time. The panic alarm can be programmed to be audible or silent. There is
no
annunciation from the keypad. A transmission will be sent to the monitoring station
ONLY if it has been programmed to
do
so by the installer.
AUTO-TEST
TRANSMISSION
The
PC
1000 can be programmed at the time of installation to send a test code
to
the
monitoring station at regular intervals. The frequency and time of the test transmission
is set by the monitoring station and should not be changed without their knowledge.
8
FIRE LOOP OPERATION
ARMED MODE ("Armed" light ON)
1.
On
alarm the signal will pulse.
2.
Enter access code to silence the signal and also disarm the panel.
3.
Press
[*l
then [7]
to
reset the smoke detector(s) if the panel has been
programmed
to
do
so;
"System" and "Ready" lights will come
ON
steadily.
DISARMED MODE ("Ready" light ON)
1.
On
alarm the signal will pulse; zone 4 and "System" lights
ON
steadily
2.
Enter access code to silence signal.
3.
Press
[*]
then [7] to reset the smoke detector(s) if the panel has been
programmed to do
so;
"System" and "Ready" lights will come ON steadily.
FIRE LOOP TROUBLE
1.
Open circuit
on
the fire loop (zone 4
);
"System" light
ON
steadily and keypad
sounder beeps.
2.
Press [#] to silence the trouble.
3.
Press
[*]then
[2] to view the source of trouble; "System" and zone 3 lights flash
to indicate a trouble
on
the fire loop (zone 4).
4.
Press[#]
to
exit view-trouble mode; "Ready" and "System" lights will come
ON
steadily.
5.
When the trouble condition is repaired, the "System" lights will
go
OFF
leaving
only the "Ready" light
ON.
TESTING
IT
IS
RECOMMENDED
THAT
THE
SYSTEM
BE
TESTED
ON
A
WEEKLY
BASIS
NOTE: Perform system tests
in
the
off-peak hours, such as early morning or late
evening.
1.
Inform the monitoring station that you are testing your system.
2.
Disarm the system ("Ready" light should be ON).
3.
Perform a battery/bell test by
pressing[*]
then [4]. The alarm will sound for
about 2 seconds.
If
a trouble occurs after the test,
press[*],
[2] to view the
trouble condition.
4.
Activate each sensor
in
turn (e.g. open a door or window). Observe the zone
light come
ON
as each sensor
is
activated. The zone light will
go
OFF
as each
sensor is restored
to
normal (door or window is closed).
5.
Press the [1] and [3] keys at the same time. The signal will sound
in
a pulsed
mode. Arm then disarm the panel to silence the signal.
Continued...
9

Other manuals for DSC PC1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PC1000 and is the answer not in the manual?

DSC PC1000 Specifications

General IconGeneral
BrandDSC
ModelPC1000
CategorySecurity System
LanguageEnglish

Related product manuals