29
PC2550 Version 1.3
[14] Zone Definitions for Zones 1 to 8
Page 16
Note: When defining zones, ASSIGN DELAY ZONES FIRST to zones 1, 2, 3....then assign the other types to the
remaining zones in any order desired.
Default 1st Digit 2nd Digit
00
Zone 1 0 = Slow, audible 0 = Delay
01
Zone 2 1 = Slow, silent 1 = Instant
01
Zone 3 2 = Fast, audible 2 = Interior
01
Zone 4 3 = Fast, silent 3 = Home-Away
02 Zone 5 4 = 24 hr...Bell
02
Zone 6 5 = 24 hr...Bell/Buzzer
02
Zone 7 6 = 24 hr...Buzzer
02
Zone 8 7 = Auxiliary Delay
8 = Day Zone
[15] 1st System Option Code
Page 17
Default Zone Light On Zone Light Off
Off Zone Light 1 ...................... Communication disabled Communication enabled
Off
Zone Light 2 ...................... Restorals on bell timeout Restorals follow zones
Off
Zone Light 3 ...................... Alarm display while armed No alarm display/armed
Off Zone Light 4 ...................... DTMF dialing Pulse dialing
Off
Zone Light 5 ...................... N/C zones EOL resistors zones
Off
Zone Light 6 ...................... Keypad [P]anic audible Silent
On
Zone Light 7 ...................... Call 1st phone only Back up to 2nd phone
Off Zone Light 8 ...................... 16th code = maid's code Normal code
[16] 2nd System Option Code
Page 17
Default Zone Light On Zone Light Off
Off Zone Light 1 ...................... Partial Closing Identified Not Identified
Off
Zone Light 2 ...................... Master code not changeable Master code changeable
Off
Zone Light 3 ...................... Bell squawk enabled Bell squawk disabled
Off
Zone Light 4 ...................... PC16 OUT enabled PC16 OUT disabled
Off Zone Light 5 ...................... TLM trouble only TLM audible when armed
Off
Zone Light 6 ...................... 1400Hz Radionics 2300Hz Radionics
Off
Zone Light 7 ...................... TLM disabled TLM enabled
Off
Zone Light 8 ...................... Access code req'd for bypass Access code not req'd
[17] 3rd System Option Code
Page 18
Default Zone Light On Zone Light Off
Off Zone Light 1 ...................... No bell during Auto-arm Bell during Auto-arm
Off
Zone Light 2 ...................... AC excluded from trouble AC included
Off
Zone Light 3 ...................... 120 second bypass of zones Zones active on power up
on power up
Off
Zone Light 4 ...................... Auto-arm cancel req. access code No code required
Off
Zone Light 5 ...................... Home-Away with delay Home-Away as interior
Off Zone Light 6 ...................... Force arm on auxiliary delay Auxiliary delay normal
Off
Zone Light 7 ...................... TX limit to 24 hr. period TX limit to armed period
Off
Zone Light 8 ...................... Show bypass status always Show bypass status/disarmed