EasyManua.ls Logo

DSC PC2550 - Installers Programming Commands

DSC PC2550
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
KEYPAD FUNCTIONS
Introduction
The PC2550RK remote keypad provides complete
information and control of the PC2550 control panel. The
panel can be fully programmed from the keypad. The 8
zone lights and the fire alarm light provide alarm and status
indication for the alarm circuits. The 6 function lights guide
the user in operating the system. The built-in buzzer lets the
user hear correct key entries and other alert signals. The 12
digit keypad is used for code entry and other programming
functions. All keypad entries are made by pressing one key
at a time.
The keypad is normally resting in the arm-disarm mode. In
this condition the zone lights are indicating the opening and
closing of zones. The Ready light comes on when all zones
are closed. The system can be directed to perform other
functions such as zone bypassing, displaying trouble
conditions, displaying alarm memory and programming by
entering one of the various [] commands described below.
Pressing the [#] key or not making any key entry for 2
minutes always returns the keypad to the arm-disarm mode.
Master Code
A default Master Security Code 1234 is programmed into
the PC2550 at the factory. The Master Security Code is used
for arming and disarming the control panel, for
programming up to fifteen additional security codes using
the [][5] command and for entering other user functions
using the [][6] command. The Master Code can be
reprogrammed if the installer leaves section [16] light 2 off.
Because the PC2550 uses EEPROM memory the codes and
other data are retained even after complete AC and battery
failure.
2nd Master Code
A second master security code xxxx can be programmed
into the PC2550. This code can be changed by the installer
only, and is useful where there are multiple panels in a
complex. The 2nd Master Code can be used as a Master
Key. The default 2nd Master Code is blank.
Installer’s Programming Code
A default Installers Programming Code 2550 is
programmed into the PC2550. This code is used with the
[][8] command by the installer to gain access to the
system in order to enter panel or communicator program
information. The Installers Programming Code may be
changed by the installer.
Arming
Check to see if the Trouble or Bypass light is on before
arming the PC2550. Close all protected doors and windows
and stop movement in areas covered by motion detectors.
Check to see that the Ready light is on (all zones are
closed). The system cannot be armed unless the Ready
light is on. Enter a [4 Digit Security Code]. As each digit is
entered the keypad buzzer will beep. If the security code
was entered incorrectly, the sounder will beep steadily for 2
seconds. If the code was entered correctly but the Ready
light was not on, the keypad will beep quickly followed by a
steady tone. When the correct code is entered, the Armed
light will come on and the keypad buzzer will beep quickly.
Exit the premises through the designated exit-entry door. At
the end of the allowed exit time all lights on the keypad will
go out except the Armed light. See the Installers
Programming [][8] Command section for instructions on
how to change the exit time. Also see, Quick Arm and At
Home Arming.
Disarming
Enter the premises through the designated exit-entry door.
The keypad buzzer will be on. Go to the keypad and enter
the [4 digit security code]. If an error is made in entering the
code, press the [#] key and enter the code again. The
Armed light will go out and the keypad sounder will stop.
The correct security code must be entered before the
allowed entry time expires. To change the entry time see
Installers Programming Command, [][8]. If an alarm
occurred while the panel was armed, the Memory light and
the Zone light which caused the alarm will start to flash
and stay flashing for 2 minutes when the panel is disarmed.
Pressing the [#] key returns the panel to the normal arm-
disarm mode.
Auto-bypass/Home-Away Arming
If a correct security code is entered, and you do not exit the
premises, the system will, at the end of the Exit delay time,
arm with interior zones automatically bypassed if those
interior zones have been programmed as Home-Away
zones. The Bypass light will come on immediately following
the arming code being entered until a delay zone is tripped
or [] [1] is entered to reactivate bypassed home-away
zones. (See programming section [14], zone definitions for
programming zones as Home-Away.)
This is a convenience feature for the user who wishes to
remain at home with the system armed. The user does not
have to manually bypass the home-away zones.
To reactivate the home-away zones that have been
automatically bypassed, press [] [1]. The Bypass light
will go out. This command is a quick method of fully arming
the system before going to bed.
Zone Bypassing
[]+[1] or []+[1]+[Access Code]
A bypassed zone will not cause an alarm. If a zone is
bypassed the panel may be armed (Ready light will be on)
even if the zone is open. Use zone bypassing when access
is needed to part of the protected area. Also, damaged
wiring or contacts on a zone may be temporarily bypassed
until repairs can be made so that the panel can be armed.
If section [18] light 3 is on, all bypassed zones will be shown
when armed. Home-Away zones that are automatically
bypassed will show as well. This feature cannot be used with
a split armed system. If section [17] light 8 is on then the
bypass status will always be shown.
To bypass zones, enter [] [1] and the zone number(s) to
be bypassed. Press [#] to return to Ready (arm-disarm
mode). To remove all bypasses, enter [] [1] [0] [#]. The
Zone lights which are on, while the Bypass light is
flashing, indicate the bypassed zones. Remember that if no
keypad entry is made for more than 2 minutes the keypad
will return to the arm-disarm mode. Then, in order to bypass
a zone the complete command must be re-entered. Once

Table of Contents

Other manuals for DSC PC2550

Related product manuals