31
PC2550 Version 1.3
[23] System Clock Times
Page 21
Default
9999 Automatic Arming Time of Day Enter 4 digits from 0 to 9.
9999 For Future Use Do not enter [✱] or [#].
9999 Test Transmission Time of Day
[24] Installer's Code
Page 21
Default Enter 4 digits from 0 to 9.
2550 Do not enter [✱] or [#].
[25] Master Code (Access Code Number 1)
Page 21
Default Enter 4 digits from 0 to 9.
1234 Do not enter [✱] or [#].
[26] 2nd Master Code
Page 21
Default Can be erased by entering [✱1111]
AAAA
Enter 4 digits from 0 to 9. Do not enter [✱] or [#].
[27] Downloading Access Code
Page 21
Default Enter 4 digits from 0 to 9.
2525 Do not enter [✱] or [#].
[28] Panel Identification Code
Page 21
Default Enter 4 digits from 0 to 9.
2501 Do not enter [✱] or [#].
[29] Communicator Format Options
Page 21
Default
1 1st Telephone Number
1
2nd Telephone Number
Enter one HEX digit from [0] to [D] for each phone number:
[0] Silent Knight/Ademco slow, 10 BPS (1400 Hz handshake) 3/1 and 4/1, 4/2 non extended format
[1] Sescoa, Franklin, DCI, Vertex, 20 BPS (2300 Hz handshake) 3/1 and 4/1, 4/2 non extended format
[2] Silent Knight fast, 20 BPS (1400 Hz handshake) 3/1 and 4/1, 4/2 non extended format
[3] Radionics, (2300/1400 Hz* handshake) 3/1, 4/2 non extended format
[4] Radionics, (2300/1400 Hz* handshake) 3/1, 4/2 non extended with parity format
[5] Sescoa super speed
[6], [7] Not used
[8] Silent Knight/Ademco slow, 10 BPS (1400 Hz handshake) 3/1 extended format
[9] Sescoa, Franklin, DCI, Vertex, 20 BPS (2300 Hz handshake) 3/1 extended format
[A] Silent Knight fast, 20 BPS (1400 Hz handshake) 3/1 extended format
[B] Radionics, (2300/1400 Hz* handshake) 3/1 extended format
[C]Radionics, (2300/1400 Hz* handshake) 3/1 extended with parity format
[D]Sescoa super speed (with identified openings/closings)
[E], [F] Not used
*See section [16] for Radionics Handshake Option
It is necessary to program a format for
each option.