Ready light ON: system is ready to be
armed.
Ready
light OFF: open zone. Zone
must be closed or bypassed before
arming.
Ready light flashing with “Armed” light
ON indicates access code 9-16
programming.
Trouble
light ON means there is a fault
on the system. Press any key to silence
keypad beeping. Press [
*
] then [2] to
display trouble type; one or more zone
lights will come ON to indicate the type
of trouble.
1 Battery
2 A.C. Power
3 Day loop
4 Telephone line
5 Communicator
6 Bell circuit
7 Smoke detector circuit
8 Clock needs resetting
Press [#]...
...when an error is made in entering
code, then enter code again.
...to return to ready state after using
[
*
] commands.
Press [F] for 2 seconds to activate
FIRE transmission.
Press [A] for 2 seconds to activate an
AUXILIARY transmission.
Press [P] for 2 seconds to activate
PANIC transmission.
When ON in the normal operating
mode, the Zone Lights indicate an
open zone. eg. open door, window,
etc. Refer to zone chart on keypad
door for zone information.
Armed
light will come ON indicating
system is armed. Ensure “Ready” light
is ON, enter [4 digit] access code.
Armed light flashing with “Ready”
light indicates access code 9-16
programming.
Memory light ON means an alarm
has occurred. To display zone that
caused alarm, press [
*
] then [3].
Zone light will come on indicating
which zone caused the alarm.
Fire
light is ON when a detector on the
fire loop is in alarm. Press any key
within 30 seconds of first alarm to get
2 minutes to reset smoke detectors.
THESE BUTTONS WILL NOT
FUNCTION UNLESS PROGRAMMED
BY INSTALLER.
Colored labels on keypad door
indicate which keys are active.
Bypass
light comes ON when you
bypass a zone. To bypass a zone,
press [
*
], [1], [Master Code] and
then the zone(s) you wish to Bypass.
Enter 01 for zone 1; 08 for zone 8; 16
for zone 16. Press [#] to return to
ready.