DSC Power 864 - Testing Your System; Section 6: Fire Safety; Household Fire Safety Audit; Fire Escape Planning

DSC Power 864
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Zone
Light
Type
Of
Trouble
Low
zone
battery.
This
trouble
is
generated
when
a
wireless
device
has
a
low
battery.
This
trouble
only
applies
if
you
have
wireless
devices
installed
on
your
system.
Press
[7]
one,
two,
or
three
times
to
view
which
devices
are
experiencing
battery
failure.
The
following
will
occur:
Keypad
beeps:
Keypad
displays:
Press
[7]
1
Zones
with
low
batteries
Press
[7]
again2
Handheld
keypads
with
low
batteries
Press
[7]
again3
Wireless
keys
with
low
batteries.
8
Loss
of
time
on
system
clock.
To
set
the
system
time,
follow
the
instruc¬
tions
in
"Setting
the
Time
and
Date"
on
page
21.
2.
T
o
exit
trouble
viewing,
press
®.
Viewing
the
Event
Buffer
from
an
LCD5500Z
The
event
buffer
will
show
you
a
list
of
the
last
256
events
that
have
occurred
on
your
sys¬
tem.
You
must
use
an
LCD5500Z
keypad
to
view
the
event
buffer.
1.
Press
®©
[master
code],
2.
To
select
Event
Buffer
viewing,
press
®.
3.
The
keypad
will
display
the
event
number,
partition
or
area,
and
the
time
and
date.
Press
®
to
switch
between
this
information
and
the
event
details.
4.
Use
the
C<][>)
keys
to
scroll
through
the
events
in
the
buffer.
5.
To
exit
event
buffer
viewing,
press
®.
Testing
Your
Testing
Your
Keypad
Sounder
and
Siren
System
The
System
Test
provides
several
system
tests,
and
a
two-second
check
of
the
keypad
sounder
and
bell
or
siren.
1.
Press
®
®
[Master
Code]
®.
2.
The
following
will
occur:
-
The
system
activates
all
keypad
sounders
and
bells
or
sirens
for
two
seconds
All
key¬
pad
lights
turn
ON.
-
LCD5500Z
keypads
will
light
all
pixels
-
The
Ready,
Armed,
and
Trouble
LED's
will
flash
for
the
duration
of
the
test
3.
To
exit
the
function
menu,
press
®.
Testing
Your
Entire
System
All
smoke
detectors
in
this
installation
must
be
tested
by
your
smoke
detector
installer
or
dealer
once
a
year
to
ensure
they
are
functioning
correctly.
It
is
the
user's
responsibility
to
test
the
system
weekly
(excluding
smoke
detectors).
Ensure
you
follow
all
the
steps
in
the
'Testing
Your
System'
section
above.
NOTE:
Should
the
system
fail
to
function
properly,
call
your
installation
company
for
service
immediately.
1.
Prior
to
testing,
ensure
that
the
system
is
disarmed
and
the
Ready
light
is
on.
2.
Press
®
and
close
all
zones
to
return
the
system
to
the
Ready
state.
3.
Perform
a
System
Test
by
following
the
steps
in
the
previous
section.
4.
To
test
the
zones,
activate
each
detector
in
turn
(e.g.,
open
each
door/window
or
walk
in
motion
detector
areas).
18

Other manuals for DSC Power 864

Related product manuals