32
disarmed and report to the central station. All other zone
types will only go into alarm if the panel is armed.
Reporting codes can be one or two digits and can use Hex
digits (A through F). The following is a description of the
different reporting codes that can be programmed and
when the events will be reported to the central station.
[324]-[325] - Alarm Restoral Reporting Codes,
Zones 1-32
If the Restoral on Bell Time-out
Restoral on Bell Time-outRestoral on Bell Time-out
Restoral on Bell Time-out option is selected the panel
will send the Zone Restoral
Zone RestoralZone Restoral
Zone Restoral Reporting Code for the zone
when the alarm output times out AND the zone is secure.
If the zone is not secured when the alarm output times out
the panel will send the restoral immediately after the zone
is secured.
If the Restoral on Bell Time-out
Restoral on Bell Time-outRestoral on Bell Time-out
Restoral on Bell Time-out option is not selected the
panel will immediately send the Zone Restoral reporting
code when the zone is secured or when the panel is dis-
armed, regardless if the alarm output is active or not.
NOTE:
24-hr type zones will report the restoral immedi-
ately after the zone is secured.
[328] - Miscellaneous Alarm Reporting Codes
Duress Alarm:
this reporting code will be transmitted to the
monitoring station whenever a Duress code is used to per-
form any function on the system.
Opening After Alarm:
this reporting code will be transmit-
ted to the monitoring station on opening if an alarm has
occurred during the previous armed period.
Recent Closing
: a Recent Closing transmission will be sent
if an alarm occurs within 2 minutes of an exit time expira-
tion. The Recent Closing report will be sent for the first
alarm only.
Zone Expander Supervisory Alarm:
this reporting code is
sent when the system loses communications with any zone
expander module (PC5108, PC5132, or keypad with on-
board zone).
Zone Expander Supervisory Restoral
: this reporting code is
sent when the system regains communications with all
zone expander modules (PC5108, PC5132, or keypad with
on-board zone) that have been enrolled on the system.
Cross Zone / Police Code Alarm:
When using Cross Zoning
(Section 018, Option 6 ON), this reporting code will be sent
when two Crossed Zones go into alarm during the cross
zone period.
When using Police Code (Section 018, Option 6 OFF), this
reporting code will be sent when any two zones go into
alarm.
If the
Double Hit
option has been enabled, this reporting
code will be sent when two zone alarms occur on the same
zone and the Burglary Verified timer has not expired.
NOTE:
Only one reporting code will be sent during each
armed to armed period when using Police Code.
Burglary Not Verified
: this reporting code will be sent after
the Burglary Verified Timer expires after a zone alarm
occurs.
Alarm Cancelled:
this reporting code will be sent if a valid
access code is entered during the Alarm Cancel window. If
a valid access code is entered during this window, then the
Alarm Cancelled event is logged and sent. When the cen-
tral station has acknowledged this reporting code/event, a
keypad ring-back will occur.
[329] - Priority Alarm and Restoral Reporting Codes
[F], [A], [P] Alarm:
this reporting code will be sent if the [F]
[A] or [P] key is used to generate manual alarms.
Auxiliary Input Alarm:
this reporting code will be sent
when PGM2 is being used for 2-wire smoke detectors and
the 2-wire smoke detector goes into alarm.
[F], [A], [P] Restoral:
this reporting code will be sent after
the [F] [A] [P] alarm reporting code is sent.
Auxiliary Input Restoral:
the panel will transmit this
reporting code when the 2-wire smoke detector has
restored after an alarm.
[330]-[331] - Tamper Reporting Codes, Zones 1-32
If the panel is programmed for Double EOL zones (see Sec-
tion 2.10 "Zone Wiring") the panel will report a
Zone
Tamper Alarm
reporting code if an open condition is
present on a zone. A different reporting code can be pro-
grammed for each zone for identification.
[334]-[335] - Tamper Reporting Codes, Zones 1-32
The
Zone Tamper Restoral
reporting code will be transmit-
ted immediately when the Tamper condition is restored.
[338] - Miscellaneous Tamper Reporting Codes
General System Tamper:
General System Tamper:General System Tamper:
General System Tamper:
a General System Tamper
General System TamperGeneral System Tamper
General System Tamper Report-
ing code will be transmitted when the tamper zone on any
module is violated.
General System Tamper Restoral:
General System Tamper Restoral:General System Tamper Restoral:
General System Tamper Restoral:
the General System
General SystemGeneral System
General System
Tamper Res to r a l
Tamper Res to r a lTamper Res to r a l
Tamper Restoral reporting code will be transmitted when
the tamper zone on the module is restored.
Keypad Lockout:
Keypad Lockout:Keypad Lockout:
Keypad Lockout: the panel will transmit the Keypad Lock-
Keypad Lock-Keypad Lock-
Keypad Lock-
out
outout
out reporting code if the lockout is activated.
[339]-[340] - Closing (Arming) Reporting Codes,
Zones 1-32
The panel will transmit a Closing
ClosingClosing
Closing reporting code to indi-
cate a partition(s) is armed. A different reporting code can
be transmitted for each User Code, Partition Master Code
and System Master Code to identify who armed the parti-
tion(s).
[341] - Miscellaneous Closing (Arming) Reporting
Codes
Closing by Duress Code 33/34:
a Closing by Duress
Closing by DuressClosing by Duress
Closing by Duress code
Reporting code will be transmitted in addition to the
Duress reporting code if a partition(s) is armed using a
Duress Code.
Closing by Master or Supervisory Code:
the panel will
transmit a Closing
ClosingClosing
Closing reporting code to indicate a partition(s)
is armed. A different reporting code can be transmitted for
each User Code, Supervisory Code and System Master
Code to identify who armed the partition(s).
Partial Closing:
a Partial Closing
Partial ClosingPartial Closing
Partial Closing reporting code will be
transmitted if a partition is armed with zones manually
bypassed. The code will also be transmitted if a partition
Auto-arms with zone(s) in violation.
Special Closing:
a Special Closing
Special ClosingSpecial Closing
Special Closing reporting code will be
transmitted if the partition(s) is armed using any of the fol-
lowing methods:
Quick Arm
Auto-arm
Arming via the DLS Software
Arming via Keyswitch
Away Function Key Arming
Arming with the Maintenance Code.
Stay Function Key arming
Late to Close
Late to CloseLate to Close
Late to Close
:
A Late to Close
Late to CloseLate to Close
Late to Close reporting code will be trans-
mitted if a partition isn't armed before the auto-arm start
time when the late to close option, (Section 017, option 5) is
enabled.
Exit Fault:
If an Exit Fault Pre-Alert
Exit Fault Pre-Alert Exit Fault Pre-Alert
Exit Fault Pre-Alert occurs and Entry Delay
expires before the system is disarmed, Exit Fault will be
logged and this reporting code will be sent.
WWW.DIYALARMFORUM.COM