EasyManuals Logo

DSC Power832PC5010 CP-01 User Manual

DSC Power832PC5010 CP-01
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
Programming Sections:
5.6 Communicator Programming PWS Sect6
33
[342]-[343] - Opening (Disarming) Reporting
Codes Access Codes 1-32
The panel will transmit an
Opening
reporting code
to indi-
cate partition(s) is disarmed. A different reporting code
can be transmitted for each user code, partition master
code and system master code to identify who armed the
partition(s).
[344] - Miscellaneous Opening (Disarming)
Reporting Codes
Opening by Duress Code 33/34:
Opening by Duress Code 33/34: Opening by Duress Code 33/34:
Opening by Duress Code 33/34: This reporting code will be
transmitted in addition to the duress reporting code if a
partition(s) is disarmed using a Duress Code
Opening by Master or Supervisory Code:
Opening by Master or Supervisory Code:Opening by Master or Supervisory Code:
Opening by Master or Supervisory Code: The panel will
transmit this reporting code to indicate a partition(s) is
armed. A different reporting code can be transmitted for
each User Code, Supervisory Code and System Master
Code to identify who armed the partition(s).
Auto Arm Cancellation:
Auto Arm Cancellation:Auto Arm Cancellation:
Auto Arm Cancellation: This reporting code is transmitted
when the Auto Arming sequence is canceled or Postponed
Special Opening:
Special Opening:Special Opening:
Special Opening: A Special Opening
Special OpeningSpecial Opening
Special Opening reporting code will
be transmitted if the partition(s) is disarmed using any of
the following methods:
Disarming using the Maintenance Code
Disarming via the DLS Software
Disarming via keyswitch
[345] - Maintenance Alarm Reporting Codes
Battery Trouble Alarm:
the panel will transmit a Battery
BatteryBattery
Battery
Trouble Alarm
Trouble AlarmTrouble Alarm
Trouble Alarm reporting code when the backup battery
drops below 11.5 V
DC
.
AC Failure Trouble Alarm:
the panel will transmit an AC
ACAC
AC
Failure Trouble Alarm
Failure Trouble AlarmFailure Trouble Alarm
Failure Trouble Alarm reporting code when the AC to the
panel is lost and the AC Failure Communication Delay
timer expires.
Bell Circuit Trouble Alarm:
a Bell Circuit Trouble Alarm
Bell Circuit Trouble AlarmBell Circuit Trouble Alarm
Bell Circuit Trouble Alarm
reporting code will be transmitted immediately if an open
condition is measured on the Bell Output of the main
panel.
Fire Trouble Alarm:
a Fire Trouble Alarm
Fire Trouble AlarmFire Trouble Alarm
Fire Trouble Alarm reporting code
will be transmitted immediately when an open condition
is measured on any fire zone.
Auxiliary Power Supply Trouble Alarm:
the Auxiliary
AuxiliaryAuxiliary
Auxiliary
Power Supply Trouble Alarm
Power Supply Trouble AlarmPower Supply Trouble Alarm
Power Supply Trouble Alarm reporting code will be
transmitted if the AUX output is shorted.
TLM Trouble:
a TLM Trouble
TLM TroubleTLM Trouble
TLM Trouble reporting code can only be
transmitted if a LINKS1000/2X50 Communicator is being
used (see Section 5.26 LINKS1000 Cellular Communica-
tor). The panel will only transmit the signal after the time
programmed for the TLM Trouble Delay.
General System Trouble:
a General System Trouble
General System TroubleGeneral System Trouble
General System Trouble report-
ing code will be transmitted if the panel detects any of the
following:
AC Power Failure
Low Battery
AUX Output Trouble
Output #1 on the PC5200/PC5204 Power Supply/Out-
put Module.
General System Supervisory Trouble:
a General System
General SystemGeneral System
General System
Supervisory Trouble
Supervisory TroubleSupervisory Trouble
Supervisory Trouble reporting code will be transmitted if
any module goes missing from the Keybus. If the module
is a zone expander the panel will also transmit the
Zone
Expander Supervisory Alarm Trouble
reporting code.
[346] - Maintenance Restoral Reporting Codes
Battery Trouble Restoral
Battery Trouble RestoralBattery Trouble Restoral
Battery Trouble Restoral: the Battery Trouble Restora
Battery Trouble RestoraBattery Trouble Restora
Battery Trouble Restoral
reporting code will not be transmitted until the battery
has been charged over 12.5 V
DC
.
AC Failure Trouble Restoral
AC Failure Trouble RestoralAC Failure Trouble Restoral
AC Failure Trouble Restoral: the AC Failure Trouble
AC Failure TroubleAC Failure Trouble
AC Failure Trouble
Restoral
RestoralRestoral
Restoral
reporting code will be transmitted once AC
power has been restored for the amount of time pro-
grammed for AC Failure Communication delays.
Bell Circuit Trouble Restoral
Bell Circuit Trouble RestoralBell Circuit Trouble Restoral
Bell Circuit Trouble Restoral: the Bell Circuit Trouble
Bell Circuit TroubleBell Circuit Trouble
Bell Circuit Trouble
Restoral
RestoralRestoral
Restoral reporting code will be transmitted as soon as the
open condition on the bell output is corrected.
Fire Trouble Restoral
Fire Trouble RestoralFire Trouble Restoral
Fire Trouble Restoral: the Fire Trouble Restoral
Fire Trouble RestoralFire Trouble Restoral
Fire Trouble Restoral reporting
code will be transmitted when the correct resistance value
is measured on any Fire type zone.
Auxiliary Power Supply Trouble Restoral
Auxiliary Power Supply Trouble RestoralAuxiliary Power Supply Trouble Restoral
Auxiliary Power Supply Trouble Restoral: the panel con-
stantly checks the AUX output, when the excessive cur-
rent draw is removed the panel will reset the output and
transmit an Auxiliary Power Supply Trouble Restoral
Auxiliary Power Supply Trouble RestoralAuxiliary Power Supply Trouble Restoral
Auxiliary Power Supply Trouble Restoral
reporting code.
TLM Restoral:
TLM Restoral:TLM Restoral:
TLM Restoral: the TLM Restoral reporting code will be
transmitted immediately after the Trouble is restored.
General System Trouble Restoral
General System Trouble RestoralGeneral System Trouble Restoral
General System Trouble Restoral: a General System Trou-
ble Restoral
reporting code will be transmitted when the
panel detects none of the following:
AC Power Failure Low Battery
AUX Output Trouble Output #1 on the PC5200 /
PC5204 power Supply/Output Module after a Trouble
was reported.
General System Supervisory Restoral
General System Supervisory RestoralGeneral System Supervisory Restoral
General System Supervisory Restoral: the General System
Trouble Restoral reporting code will be transmitted when
the control panel detects all modules enrolled on the key-
bus
[347] - Miscellaneous Maintenance Reporting Codes
Telephone Number 1 (2) FTC Restore:
Telephone Number 1 (2) FTC Restore:Telephone Number 1 (2) FTC Restore:
Telephone Number 1 (2) FTC Restore: if the panel fails to
transmit information to the central station it will display a
failure to communicate Trouble condition. The panel will
transmit a Phone Number 1 Failure
Phone Number 1 FailurePhone Number 1 Failure
Phone Number 1 Failure to Communicate
reporting code or a
Phone Number 2 Failure to Communi-
cate
reporting code the next time it calls the central sta-
tion. The panel will transmit the old events, followed by
the failure to communicate, followed by the new events.
Event Buffer 75% Full:
Event Buffer 75% Full:Event Buffer 75% Full:
Event Buffer 75% Full: If the event buffer is uploaded on a
regular basis an Event Buffer 75% Full
Event Buffer 75% FullEvent Buffer 75% Full
Event Buffer 75% Full reporting code can
be transmitted to warn that the Buffer is almost full.
DLS Lead In:
DLS Lead In:DLS Lead In:
DLS Lead In: The DLS Lead In
DLS Lead InDLS Lead In
DLS Lead In reporting code will only
be transmitted if the DLS Call Back feature is being used
(see Section 5.8 "Downloading"). Before the panel calls the
computer back it will call the central station and transmit
the reporting code to indicate a download session is
about to begin.
DLS Lead Out:
DLS Lead Out:DLS Lead Out:
DLS Lead Out: After a downloading session is attempted
and/or completed, the panel will transmit a DLS Lead
DLS LeadDLS Lead
DLS Lead
Out
OutOut
Out reporting code.
Zone Fault Alarm:
Zone Fault Alarm:Zone Fault Alarm:
Zone Fault Alarm: The Zone Fault Alarm
Zone Fault AlarmZone Fault Alarm
Zone Fault Alarm reporting code
will be transmitted when there is a short detected on any
DEOL zone and/or a loss of Supervisory on a wireless
zone.
Zone Fault Restoral:
Zone Fault Restoral:Zone Fault Restoral:
Zone Fault Restoral: The Zone Fault Restoral
Zone Fault RestoralZone Fault Restoral
Zone Fault Restoral reporting
code will be transmitted when the fault condition on the
zone is corrected.
Delinquency Code:
Delinquency Code:Delinquency Code:
Delinquency Code: The Delinquency
DelinquencyDelinquency
Delinquency reporting code is
sent whenever the panel is not armed within the number
of days programmed for the Delinquency Transmission
Delay.
General Zone Low Battery Alarm:
General Zone Low Battery Alarm:General Zone Low Battery Alarm:
General Zone Low Battery Alarm: the panel will transmit
a General Zone Low Battery Alarm
General Zone Low Battery AlarmGeneral Zone Low Battery Alarm
General Zone Low Battery Alarm reporting code when
a wireless detector indicates a low battery condition and
the delay programmed in Zone Low Battery Transmission
Delay expires.
General Zone Low Battery Restoral:
General Zone Low Battery Restoral:General Zone Low Battery Restoral:
General Zone Low Battery Restoral: the General Zone
Low Battery Restoral reporting code will be transmitted
when the low battery condition on all wireless zones is
corrected. The specific zone that caused the trouble will
be stored to the event buffer.
WWW.DIYALARMFORUM.COM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Power832PC5010 CP-01 and is the answer not in the manual?

DSC Power832PC5010 CP-01 Specifications

General IconGeneral
BrandDSC
ModelPower832PC5010 CP-01
CategorySecurity System
LanguageEnglish

Related product manuals