Self Contained Wireless Alarm System v1.0
24
[375] System Maintenance Communicator Call Directions
[376] System Test Transmissions Communicator Call Directions
[377] Communication Variables
Default
003
I___0__I__0__I___1__I Swinger Shutdown (Alarms and Rest) 001-014 Transmissions
003
I_______I______I_______I Swinger Shutdown (Tampers and Rest) 001-014 Transmissions, 000=disabled on Non CP-01 Systems
003
I_______I______I_______I Swinger Shutdown (Maint. and Rest) 001-014 Transmissions, 000=disabled
000
I___0__I__3__I___0__I Communication Delay 000-255 seconds
030
I_______I______I_______I AC Failure Communication Delay 001-255 minutes/hours, 000=disabled
EU
002
NA
010 I_______I______I_______I TLM Trouble Delay 003-255 seconds x3 (e.g.,003 = 9 seconds)
030
I_______I______I_______I Test Transmission Cycle (land line) 001-255 days/hours††
000
I_______I______I_______I Future Use
007
I_______I______I_______I Zone Low Battery Transmission Delay 000-255 days
030
I_______I______I_______I Delinquency Transmission Cycle 000-255 days/hours†††, 000=disabled
000
I___0__I__0__I___5__I Communications Cancelled Window 000-255 minutes
Dependent on programming in section [382], option [6]
††Dependent on programming in section [023], option [4]
†††Dependent on programming in section [380], option [8]
.
[378] Test Transmission Time of Day
Default
[380] First Communicator Options
Section
Option 1
First Telephone
Number (Default ON)
Option 2
Second Telephone
Number (Default OFF)
Option 3-8
Not Used
(Default OFF)
[375]
I________I I________I I________I
Section
Option 1
First Telephone
Number (Default ON)
Option 2
Second Telephone
Number (Default OFF)
Option 3-8
Not Used
(Default OFF)
[376]
I________I I________I I________I
For UL installations, the Entry Delay plus Communication Delay time must not exceed 60 seconds.
9999
I_______I_______I_______I_______I Valid entries are 0000-2359 (9999 to disable)
Opt Def. ON OFF
1
Communications Enabled
Communications Disabled
2
Restorals on Bell Time-out
Restorals Follow Zones
3
Pulse Dialing
DTMF Dialing
4
Future Use
5
Future Use
6
Alternate Dial (1st & 3rd)
Call 1st Number, Backup to 3rd
7
Future Use
8
Delinquency Follows Zone Activity (Hours)
Delinquency Follows Arming (Days)
WWW.DIYALARMFORUM.COM

Other manuals for DSC PowerSeries

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries and is the answer not in the manual?

DSC PowerSeries Specifications

General IconGeneral
ModelPowerSeries
CategorySecurity System
CommunicationPSTN, IP
Power Supply16.5VAC
Backup Battery12V 7Ah
ProgrammingVia keypad
CompatibilityDSC peripherals and modules

Related product manuals