EasyManua.ls Logo

Dual 1229 Q - Change Cycle Malfunctions; Turntable Stops After Setdown Troubleshooting

Dual 1229 Q
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fig.22
Change
cycle
177
178
179
Fig.
23
Fig.
24
1119:LLI-Littij,,.
'''''
rztti4
4'
.1
-
)'‘
I
171
173
172
156
207
As
the
record
is
dropped
the
cam
follower
lever
(207)
is
turned
to
its
start
position
by
the
cam
rocker
(173),
so
that
the
tone
arm
can
swing
in
toward
the
record
and
be
lowered
on
to
it.
If
there
are
no
more
re—
cords
on
the
spindle,
and
the
cam
rocker
cannot
turn
the
cam
follower
lever,
the
lever
remains
in
its
stop
position
and
allows
the
tonearm
to
swing
to
its
rast
position.
When
the
main
cam
(165)
returns
to
its
neu—
tral
position,
the
switch
arm
(188)
drops
into
a
cut—out
in
the
main
cam,
opening
the
power
switch
(129)
and
disengaging
the
drive
idler
(131).
Trouble
Turntable
stops
after
automatic
setdown
of
the
tonearm
Cause
a)
Switch
arm
(188)
is
not
latched
by
pawl
(273).
Bolt
of
segment
slips
over
pawl
instead
of
engagin
it.
b)
Power
switch
opens
c)
Square
bar
not
properly
screwed
in.
Paul
can
escape.
Remedy
a)
Adjust
segment
(201)
so
that
bolt
catches
pawl
in
both
positions
of
mode
selector.
b)
By
aligning
angle
lever
(145)
(play
bet—
ween
angle
lever
and
slide
(140)
max.
0.3
mm).
c)
Loosen
screw
(256).
Press
pawl
against
square
bar
(274)
(arrow
in
Fig.
24)
and
fasten
screw.
Trouble
Tonearm
misses
1/2
inch.
record
during
cy—
cling
moving
in
or
out.
Cause
Switch
arm
maladjusted.
Paul
touches
square
bar.
Remedy
After
loosening
screw
(189),
twist
short
part
of
the
switch
arm
on
the
long
part.
Adjustment
is
correct,
when
the
distance
between
pawl
and
square
bolt
(274,
mounted
on
chassis
plate)
is
0.3
mm
after
the
tone
arm
has
moved
in
and
the
main
cam
was
turned
manually.