Tonearm
and
Tonearm
Bearing
Fig.
9
Tonearm
bearing
assembly
Tubular
tonearm,
extra
lightweight,
torsionally
rigid
tonearm
of
the
Dual
1229
Q
pivots
both
horizontally
and
vertically
on
needle
bea—
rings
and
precision
ball
bearings
in
harde—
ned
and
polished
races.
lt
is
suspended
in
a
gimbal
arrangement.
This
keeps
friction
to
a
minimum.
Vertical
pivot
friction
=
0.007
gram
Horizontal
pivot
friction
=
0.015
gram
referred
to
stylus
tip
The
arm
is
thus
able
to
track
extremely
well.
The
tonearm
head
is
removable.
Before
set—
ting
the
tracking
force
for
the
cartridge
being
used,
set
the
tracking—force
scale
to
zero
and
balance
the
tonearm.
Initial
ba—
lance
is
by
sliding
the
counterweight
(74).
Final
adjustment
is
by
turning
the
weight.
You
can
balance
cartridges
with
a
weight
of
1
to
10
grams.
To
reduce
the
effects
of
small
shock
im—
pulses
on
the
arm,
the
counterbalance
weight
is
resiliently
mounted
on
a
threaded
spindle,
and
friction—braked
to
prevent
accidental
rotation.
The
cartridge
holder
will
accept
all
cartridges
with
international
standard
mounting
centers
of
1/2
inch.
Stylus
force
is
set
by
turning
a
calibrated
housing
(78),
which
stresses
or
releases
a
spiral
spring
contained
inside.
The
scale
adjustment
is
calibrated
from
0
3
p,
from
0
1.5
p
at
1/10
p
and
from
1.5
3
p
at
1/4
p
intervals.
Tracking
forces
of
mors
than
3
p
can
be
ad—
justed
with
the
help
of
the
counter—weight
on
the
tonearm;
turning
left
(counter—clock—
wise)
increases
the
tracking
force
by
1/2
p
per
complete
turn.
To
replace
the
tonearm
and
bearing
assembly,
follow
these
steps:
1.
Set
stylus
force
dial
to
zero
and
mo—
de
selector
to
"single".
2.
Fasten
unit
in
repair
jig
and
turn
upside
down.
3.
Unsolder
tonearm
bade.
4.
Remove
main
lever
(184)
and
linking
layer
(270).
5.
Unhook
springe
(237,
241,
269
and
unscrew
protective
plate
(233
.
6.
Remove
washer
(266)
and
skating
lever
(267).
7.
After
removing
lock
wacher
(272)
and
sliding
disc
(271),
remove
shut—off
slide
(253)
from
segment
(201).
8.
Loosen
hex
nut
(236).
Pull
off
guide
(198)
and
lock
wacher
(199).
After
unscrewing
positioning
sleeve
(200),
lift
plata
with
lifting
pin
(203)
and
segment
(201)
can
be
removed.
9.
Turn
the
unit
back
in
its
normal
po—
sition.
10.
Set
mode
selector
on
"multi",
then
rotate
the
tonearm
bearing
frame
(58)
counter—clockwise
until
it
cannot
turn
anymore.
The
tonearm
can
then
be
lif—
ted
out.
61
62
58
60
59
Fig.
10
Tonearm
assembly
sequence