Important information
2.4 General safety information
i When operating this device always observe all
guidelines, laws, and other rules and regula-
tions that are applicable at the site of opera-
tion�
i Prior to each use, check condition of the de-
vice and make sure it is in perfect working or-
der
i Do not convert or modify the units�
i Observe the Installation and Operating In-
structions�
i Make the Installation and Operating Instruc-
tions available to the person operating the de-
vice at all times�
2.5 Combining devices safely
Take care when connecting units together or to
parts of other systems as there is always an ele-
ment of risk (e�g� due to leakage currents)�
i Only connect units when there can be no
question of danger to operator or to patient�
i Only connect units when it is safe to do so
and there is no risk of damage or harm to the
surroundings�
i If it is not 100% clear from the unit data sheet
that such connections can be safely made or
if you are in any doubt, always get a suitably
qualified person (e�g� the manufacturer) to ver-
ify that the setup is safe�
Where applicable, the requirements for medical
products have been taken into account in the
development and construction of the device� As
a result, this device is suitable for installation
within medical supply equipment�
i Where this device is installed within other
medical supply equipment, the requirements
set out in Directive 93/42EEC and the rele-
vant standards must be complied with�
A copy of the system manufacturer‘s
declaration in accordance with Article
12 of Directive 93/42/EEC can be
found in our download section at
www�duerrdental�com (document no�
9000-461-264)�
2 Safety
Dürr Dental has designed and constructed this
device so that when used properly and for the
intended purpose there is no danger to people
or property� Nevertheless, residual risks can re-
main� You should therefore observe the follow-
ing notes�
2.1 Intended purpose
The suction unit provides the dental treatment
unit with vacuum and volume flow
2.2 Intended use
Working in combination with the suction unit
with treatment unit, suction handpiece and can-
nula, the media used in dental treatment (e�g�
water, saliva, dentine and amalgam) are re-
moved by suction for disposal�
This unit is technically suitable for the aspiration
of nitrous oxide (laughing gas)� However, when
assembling a system for aspiration of nitrous
oxide, it is important to ensure that the other
components in the system are also suitable for
this purpose� Those responsible for setting up
the system must assess this and approve and
release the system for the aspiration of nitrous
oxide�
Operation with nitrous oxide is only per-
mitted if the exhaust air is transported
from the unit to the outside of the build-
ing�
2.3 Improper use
Any other usage or usage beyond this scope is
deemed to be improper� The manufacturer ac-
cepts no liability for damages resulting from this�
In these cases the user/operator will bear the
sole risk�
i Do not use this device to aspirate flammable
or explosive mixtures�
i The unit must not be used as a vacuum
cleaner
i Do not use chemicals containing chlorine or
foaming chemicals�
i Operation in operating theatres of explosive
areas is not permissible�
i The following suction units must not be set up
in the patient environment (within a radius of
1�5m): V600, V900S and V1200S�
EN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Durr Dental V 900 S and is the answer not in the manual?

Durr Dental V 900 S Specifications

General IconGeneral
ModelV 900 S
ManufacturerDürr Dental
Number of treatment unitsUp to 9
Voltage230 V
Frequency50/60 Hz
Power consumption1.1 kW
TypeDental Vacuum System