H40, H50, H50VSD-C
Jul ‘17
- 4 -
Correct
Oil Level
Quick Start (cont’d)
Lubrication.
(Refer to Page 11)
Rotation.
(Refer to Page 13)
Ensure the oil level
in the Air End is to
the level as shown
while at rest.
Check the oil after
the Unit has been at
rest for a minimum
of 5 minutes.
Oil Fill Port
Oil Drain Valve
Oil Drain Tube
External Oil Level Indicator
showing proper oil level
when Unit is off
Fixed Speed Units:
Units are equipped with Advanced Phase
Detection feature which prevents Units
from rotating in the reversed direction.
An ‘E:0090 Phase Sequence’ Error will
appear on the Controller Screen if the
phase sequence is incorrect. If this occurs,
simply switch the incoming leads ‘L1’ and
‘L3’ at the Control Panel
Note: Units with serial number 077771 and
earlier may be equipped with Anti-Rotation
Switches.
‘E:0902 Anti Rotation’ will appear on the
Controller Screen if the rotation is incorrect.
If this occurs, change ‘L1’ and ‘L3’ to the
Control Panel.
Arrows Indicate
Correct Rotation
Picture from Front of Unit
Picture from Rear of Unit
Variable Speed Units:
The Inverter to the Motor is pre-wired at the
factory.
Remove the Cover Plate from the Coupling
area and pay close attention to the arrow
indicating the correct rotation.
To verify the correct rotation, start the Unit
and turn off immediately using the
Emergency Stop Button.
If the rotation is not correct, simply change
two of the power leads to the Unit.