C1015-II-C
Jun ‘21
- 1 -
Please read this manual before
installing or using your Air
Compressor Unit. It contains
valuable information that will
help in the receiving,
installation, use, and
maintenance of the Unit.
Please keep this manual in a
safe place for future reference.
All of the information, policies, and
procedures in this reference manual apply
exclusively to DV Systems.
If you require assistance, please contact your local DV Systems Distributor or Authorized Service
center. You may contact the manufacturer directly as follows:
Phone: (705) 728-5657
Web: www.dvsystems.com
Email: sales@dvsystems.com
Contents: Page:
Quick Start ……………............................................. 2
Safety Precautions ………………………………… 4
Unpacking and Inspection …………………………... 5
Installation Mechanical …………………………. 6
Lubrication …………………………………………. 8
Installation Electrical ………………………………. 9
Start-up Procedures ………………………………. 12
Preventative Maintenance Schedule ……………. 13
Common Compressor Faults ………………..……… 15
Separator Filter & Refrigerated Air Dryer …………. 19
Trouble-Shooting Guide ……………………………… 22
Warranty ……………………………………………….. 25
C10 (T) (TD)
C15 (T) (TD)
C15VSD (T) (TD)
Rotary Screw
Air Compressor
Units
- - -
Installation
And
Start-up Data

Questions and Answers

  • D
    Debbie RiceAug 17, 2025
    What to do if my DV Systems Air Compressor is overheating?
    • N
      Neil DuranAug 17, 2025
      If your DV Systems Air Compressor is overheating, it could be due to several factors: high ambient temperature, blocked air circulation, a dirty heat exchanger, low oil level, using the wrong type of oil, a faulty thermo valve, a blocked oil filter, a faulty temperature sensor or thermostat, high pressure, or an open cabinet door/panel. Solutions include checking and improving air circulation, cleaning the heat exchanger, adding the correct type of oil, checking and repairing the thermo valve, replacing the oil filter, checking the wiring to the temperature sensor and replacing it if necessary, replacing the thermostat, lowering the pressure setting, and securing the cabinet door/panel.
  • M
    Michael AguilarAug 21, 2025
    Why is my DV Systems Air Compressor consuming too much oil?
    • R
      Richard RobertsonAug 21, 2025
      Excessive oil consumption in your DV Systems Air Compressor can stem from several causes: the oil level being too high, a blocked oil return line, a saturated oil separator, using the wrong type of oil, operating the unit at too high a temperature, an oil leak, or light unit load or excessive load/idle cycles. Suggested actions include reducing the oil level, cleaning or replacing the scavenge in-line filter, replacing the oil separator, switching to the factory-recommended oil, addressing high operating temperatures, repairing any oil leaks, and ensuring the unit operates at correct pressures with a minimum 10 psi differential, also considering if the unit is oversized for the tank capacity.
  • T
    Tony JohnsonAug 25, 2025
    Why is there no or insufficient air flow from my DV Systems Air Compressor?
    • N
      Nicholas MarshallAug 25, 2025
      If your DV Systems Air Compressor has no or insufficient airflow, it could be due to a dirty air filter, a blocked oil separator, a faulty intake valve, air leaks in the system, incorrect pressure limits, an open blowdown solenoid valve, or broken or slipping belts. To resolve this, replace the air filter or oil separator, repair or replace the intake valve, check for and fix air leaks, adjust the pressure settings, check the wiring to the solenoid valve and replace if necessary, and check the belt tension and condition.
  • R
    Ronald MuellerAug 27, 2025
    What to do if my DV Systems Air Compressor surges?
    • S
      solomonrobinAug 27, 2025
      If your DV Systems Air Compressor is surging, the cause may be a restriction in the heat exchanger or hoses, an incorrect or malfunctioning pressure transducer setting, a blockage at the unit outlet, the dryer freezing up, or an undersized air receiver. Try flushing out or replacing the heat exchanger or hoses, setting the pressure as per instructions or replacing the transducer, checking for obstructions in the outlet piping, verifying the dryer parameters and increasing the dew point if needed, and using a minimum 120-gallon air receiver for 7-1/2 to 15 HP Units.
  • K
    Kevin AshleyAug 31, 2025
    Why does my DV Systems Air Compressor start slowly?
    • A
      Alexis RobinsonAug 31, 2025
      A slow start in your DV Systems Air Compressor could be caused by an intake valve not functioning properly, low ambient temperature, the minimum pressure valve leaking back to the air end, the minimum pressure valve setting being too high, or using the wrong type of oil. Try checking the intake valve operation and repairing or replacing it as needed, stopping and restarting once the ambient temperature increases, repairing or replacing the minimum pressure valve, adjusting the minimum pressure valve setting to 65 psi, or changing to the factory-recommended oil.
  • N
    nicole53Sep 3, 2025
    Why is my DV Systems Air Compressor showing fault alarms?
    • L
      Lisa HolmesSep 3, 2025
      Fault alarms on your DV Systems Air Compressor can be triggered by several issues: the emergency stop button being pressed, high or low temperature, or high pressure. Ensure the emergency stop button is not pressed. If high temperature, see ‘Section C’. If low temperature, increase ambient temperature to 10°C. For high pressure, check the pressure settings, the pressure transducer, and the wiring to the transducer.
  • A
    Alexander WilliamsSep 7, 2025
    Why does the intake valve on my DV Systems Air Compressor leak oil when the unit stops?
    • L
      laurenhernandezSep 7, 2025
      Oil leaking from the intake valve of your DV Systems Air Compressor when it stops can be due to a leaking intake valve seal, the intake valve being stuck in the open position, or a malfunctioning blowdown solenoid. Repair the intake valve using an intake valve repair kit, repair or replace the intake valve, or replace the solenoid.
  • R
    Richard RodriguezSep 10, 2025
    Why does my DV Systems Air Compressor have high power consumption?
    • W
      William DaughertySep 10, 2025
      High power consumption in your DV Systems Air Compressor can be attributed to improper air pressure settings, a malfunctioning blowdown solenoid, low voltage or phase imbalance in the building's electrical supply, or a failing motor. Reset the pressure to factory defaults, inspect or replace the blowdown solenoid, contact an electrician to verify the voltage, and have the motor inspected.
  • S
    Savannah MayNov 13, 2025
    Why won't my DV Systems Air Compressor start?
    • C
      crawfordlisaNov 13, 2025
      Your DV Systems Air Compressor might not start due to several reasons. There could be no power reaching the unit, loose or missing wires, the Emergency Stop Button might be pressed, the Motor Overload could be tripped, the compressor might be overheated or stopped by over-pressure, the unit might have timed out because the pressure hasn't dropped below 120 psi, or there could have been a power interruption. Suggested solutions include checking the power at the disconnect or breaker, ensuring all wiring connections are tight, releasing the Emergency Stop Button, resetting the overload, ensuring sufficient airflow and appropriate ambient temperature, cleaning the Heat Exchanger, checking/replacing faulty components like the Temperature Switch or Solenoid Valve, addressing leaks, lowering the...

Summary

Quick Start

Safety Precautions

Warning Symbols and Definitions

Explains the meaning of WARNING, CAUTION, and NOTE symbols used in the manual.

Common Hazards and Safeguards

Details potential hazards during operation and necessary safety measures.

Mechanical Installation

Unit Location Requirements

Specifies ideal placement conditions, clearances, and anchoring for the unit.

Lubrication

Electrical Installation

General Electrical Safety

Emphasizes safe electrical connections by competent electricians and adherence to codes.

Fused Disconnects and Fuses

Guidance on selecting and installing appropriate fused disconnects and fuses.

Motor and Air End Rotation

Start-up Procedures

Initial Unit Startup Steps

A step-by-step guide for the initial startup of the compressor unit.

Preventative Maintenance Schedule

Maintenance Interval Chart

Common Compressor Faults

CSC300 Controller Alarms

Lists common alarms, their descriptions, and checks to perform.

CSC300 Controller Shutdown Errors

Lists shutdown error codes, their descriptions, and checks to perform.

Variable Speed Drive (VSD)

VSD Operating Screen and Status

Common VSD Fault Codes

Separator Filter and Air Dryer

Trouble Shooting Guide

Unit Wont Start Troubleshooting

Causes and corrections for startup failures.

Insufficient Air Flow Troubleshooting

Unit Overheating Troubleshooting

Slow Compressor Start Troubleshooting

Fault Alarms Troubleshooting