SDI-W
Feb ‘19
- 1 -
Contents: Page:
Safety Precautions 2
Preventative Maintenance Schedule 3
Unpacking and Inspection 4
Compressor Terminology 5
Installation – Mechanical 6
Lubrication 7
Installation - Electrical 8-9
Start-up Procedures 10
Compressor Unit Parts 11-12
Compressor Pumps 13-15
Trouble Shooting Guide 16-19
DV Systems Limited Warranty 20
Please read this manual before
installing or using your Air
Compressor Unit. It contains
valuable information that will
help in the receiving,
installation, use, and
maintenance of the Unit.
Please keep this manual in a
safe place for future reference.
All of the information, policies, and
procedures in this reference manual apply
exclusively to DV Systems.
DV Systems Inc.
490 Welham Road
Barrie, ON
L4N 8Z4
Tele: (705) 728-5657
Web: www.dvsystems.com
Email: sales@dvsystems.com
Standard Duty
Industrial
‘IS’ and ‘SDI’
Air Compressor
Installation,
Maintenance,
And
Service Data

Questions and Answers

  • S
    staylorSep 12, 2025
    Why does the unloader constantly leak when DV Systems IS5-5580 is off?
    • R
      rsanfordSep 12, 2025
      If the unloader leaks constantly when your DV Systems Air Compressor unit is not operating, the disc inside the tank check valve is not seating properly, allowing compressed air to escape. Clean or replace the check valve as required.
  • B
    burtonkimberlySep 13, 2025
    What happens if my DV Systems IS5-5580 Air Compressor pump seizes?
    • K
      Katie FosterSep 14, 2025
      If your DV Systems Air Compressor pump seizes and the pump started without oil, it will require a complete overhaul, during which the defective parts must be replaced.
  • N
    Nathan WatkinsSep 15, 2025
    What should I do if there's a crack in the air receiver of my DV Systems IS5-5580 Air Compressor?
    • P
      Peter OchoaSep 16, 2025
      Do not attempt to repair the tank of your DV Systems Air Compressor if there is a crack in the air receiver. Also, do not continue to operate the compressor unit. Contact your local distributor for further guidance.
  • M
    Mr. Frank LopezNov 26, 2025
    Why is my DV Systems Air Compressor making excessive noise?
    • A
      alexander18Nov 27, 2025
      Excessive noise in your DV Systems Air Compressor can stem from several causes. Start by tightening any loose belt guards, flywheels, or motor pulleys. Inspect the valves in the cylinder head to ensure they are seated correctly and re-torque as necessary. If the noise occurs during start-up, tighten the belts until no slippage is apparent. Make sure the unit is mounted level, using vibration pads. Use the correct DV Systems oil and check that the level is correct. Clean any carbon or foreign material from the piston head and check cylinder walls for scoring. If the sound is amplified through the floor or intake, mount the unit on vibration isolators and insulate the intake piping. If the pump is knocking, the bearings may be worn and need replacement. Worn connecting rod bearing inserts ca...

Summary

Safety Precautions

Safety Symbol Definitions

Explains safety symbols indicating hazards, damage prevention, and important information.

Common Hazards and Safeguards

Lists common hazards during operation and recommended safeguards.

Preventative Maintenance Schedule

Mechanical Installation Guidelines

Unit Location and Environment

Guidelines for selecting an appropriate installation location and environmental conditions.

Mounting, Anchoring, and Clearances

Instructions for secure mounting, anchoring, and maintaining necessary clearances.

Critical Installation Warnings

Highlights crucial warnings regarding tank anchoring and indoor use.

Lubrication Procedures

Electrical Installation Basics

Electrical Safety and Wiring

Emphasizes safe electrical connection by a licensed professional and grounding requirements.

Magnetic Starter and Wiring Diagrams

Explains the magnetic starter's role and provides typical wiring diagrams.

Electrical Installation Details

Motor Voltage and Warranty

Details motor voltage requirements and warranty information.

Pump Rotation for Cooling

Explains correct pump rotation for efficient cooling.

Importance of Licensed Electricians

Outlines why hiring a licensed electrician is crucial for installation.

Start-up Procedures

Initial Start-up Steps

A step-by-step guide for the initial start-up of the compressor unit.

Trouble Shooting Guide - Start-up & Flow

Trouble Shooting Guide - Noise & Oil

Trouble Shooting Guide - Overheating & Belts