USER’S MANUAL AND OPERATING INSTRUCTIONS
C US
PROPANE
CONSTRUCTION HEATER
GENERAL HAZARD WARNING
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH
THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS,
OR DAMAGE FROM THE HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, CARBON
MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD
USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION
MANUAL, LABELS, ETCETERA, CONTACT THE MANUFACTURER.
CONSUMER: Retain this manual for future reference.
50-10-104 Printed in China Rev. 2013-06-05
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
RMC-FA40DGD (40,000 BTU/HR, FORCED - AIR)
RMC-FA50DGD (30,000/50,000 BTU/HR, FORCED - AIR)
RMC-FA60DGD (30,000/60,000 BTU/HR, FORCED - AIR)
RMC-FA100DGD (70,000/100,000 BTU/HR, FORCED - AIR)
RMC-FA125DGD/LPFA125DGD (70,000/125,000 BTU/HR, FORCED - AIR)
RMC-FA150DGD (120,000/150,000 BTU/HR, FORCED - AIR)
RMC-FA40/DGP/DGP-01 (40,000 BTU/HR, FORCED - AIR)
RMC-FA50/DGP/DGP-01 (30,000/50,000 BTU/HR, FORCED - AIR)
RMC-FA60/DGP/DGP-01 (30,000/60,000 BTU/HR, FORCED - AIR)
RMC-FA100/DGP/DGP-01 (70,000/100,000 BTU/HR, FORCED - AIR)
RMC-FA125/DGP/DGP-01 (70,000/125,000 BTU/HR, FORCED - AIR)
LPFA125H/LPFA125H-01
RMC-FA150/DGP/DGP-01 (120,000/150,000 BTU/HR, FORCED - AIR)
Dyna-Glo™DELUX
MODELS:
Dyna-Glo™Pro
MODELS:
ANS Z83.7-2011 CSA 2.14-2011
Adequate ventilation must be provided.
FA40DGP-01
FA60DGP/DGP-01 LPFA125H/H-01

Questions and Answers

  • D
    Daniel CrossJul 28, 2025
    What to do if my Dyna-Glo DELUX Heater quits while running?
    • J
      Jessica WhiteJul 28, 2025
      If your Dyna-Glo Heater stops running, it could be due to several reasons. The internal temperature might be too high, causing the limit switch to shut down. Ensure the heater's output isn't restricted by obstructions. Additionally, a damaged control valve or a build-up of dust or debris inside the heater could be the cause. Consider replacing the control valve and cleaning the inside of the heater.
  • T
    Tammy AvilaAug 6, 2025
    Why Dyna-Glo DELUX will not fire?
    • L
      lknightAug 6, 2025
      If your Dyna-Glo Heater won't ignite, it could be due to several reasons related to the ignition system. First, check the ignitor wire for looseness and re-attach or tighten it. Also, verify the spark module and replace it if necessary. Ensure that the spark gap is set correctly according to the specifications. Finally, a bad electrode might be the cause, so consider replacing the spark plug.
  • J
    Joy BrownAug 15, 2025
    How to fix a Dyna-Glo Heater when the fan does not turn on?
    • K
      kanephillipAug 15, 2025
      If the fan on your Dyna-Glo Heater isn't turning on after making an electrical connection, there could be several reasons. First, ensure there is electric power reaching the heater by checking the current to the outlet. Inspect the heater housing for damage and make sure there are no obstructions to the fan. If the fan blades are bent, straighten them to match the others. If none of these steps work, the fan motor may be defective and require replacement.

Summary

Product Introduction and Safety

General Hazard Warnings

Crucial safety warnings about potential dangers when operating the heater.

Specifications

Technical Specifications Table

Detailed technical data including input rating, gas consumption, and electrical requirements.

Safety Instructions

General Safety Instructions

Essential safety guidelines for operating the propane construction heater.

Important Safety Instructions

Specific critical safety points to follow for safe and effective use of the heater.

Setup and Installation

Unpacking Heater

Steps for safely removing the heater from its packaging and checking for damage.

Propane Cylinder Information

Information on selecting appropriate propane tanks for heater operation.

Installation to Propane Tank

Instructions for connecting the heater to a propane gas supply cylinder.

Operation Procedures

Leak Checking

Procedure for verifying gas connections are secure and leak-free.

Lighting Instructions

Step-by-step guide for safely starting the construction heater.

Shutdown Instructions

Steps for safely turning off and disconnecting the heater.

Troubleshooting and Maintenance

Troubleshooting

Common issues and their solutions for the propane construction heater.

Maintenance Instructions

Procedures for keeping the heater in good working condition.

Technical Information

Wiring Diagrams

Electrical schematics illustrating the heater's internal connections for service.

Parts and Warranty

Replacement Parts List

Comprehensive list of available parts for ordering replacements and maintaining the heater.

Illustrated Parts Breakdown

Visual guide identifying each component of the construction heater.

Warranty

Details the terms and conditions of the manufacturer's limited warranty.

Warranty Registration

Instructions on how to register the product's warranty for coverage.

Dyna-Glo DELUX Specifications

General IconGeneral
BrandDyna-Glo
ModelDELUX
CategoryHeater
LanguageEnglish

Related product manuals