1
Propane
IR6PTDG-1/PMDG-1
IR12PTDG-1/PMDG-1
IR18PTDG-1/PMDG-1
IR30PTDG-1/PMDG-1
Natural Gas
IR6NTDG-1/NMDG-1
IR12NTDG-1/NMDG-1
IR18NTDG-1/NMDG-1
IR30NTDG-1/NMDG-1
VENT-FREE INFRARED
GAS WALL HEATER
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
WARNING: This appliance is equipped for
(natural or propane) gas. Field conversion is not
permitted.
- Do not store or use gasoline or other ammable vapors and Iiquids in vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed by a qualied installer, service agency or the
gas supplier.
This is an unvented gas-red heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Air For Combustion and Ventilation section on page 8 of this manual.
This appliance may be installed in an aftermarket, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
C US
C US
ANS Z21.11.2-2013
Gas Fired Room Heaters
Volume II - Unvented Room Heaters
IMIR - 2016-04-18
MODEL #
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-877-447-4768, 8:30 a.m. – 4:30 p.m., CST, Monday – Friday or
email us at customerservice@ghpgroupinc.com.

Questions and Answers

  • J
    John HerreraJul 27, 2025
    Why does my Dyna-Glo IR6PMDG-1 shut off after a few minutes?
    • B
      Brittany ReedJul 28, 2025
      If your Dyna-Glo Heater shuts off after running a few minutes, here are some possible causes and solutions: * Ensure the gas supply is turned on and the equipment shutoff valve is open. * Make sure the control knob is fully pressed in while pressing the Ignitor. * If there's air in the gas lines from installation, keep holding down the control knob and repeat the igniting operation until the air is removed. * The ODS/pilot might be clogged; clean it or replace the ODS/pilot assembly. * Verify the control knob is in the PILOT position. * If using propane, the gas supply may be depleted; contact your local propane/LP gas company.
  • P
    ptaylorAug 1, 2025
    What to do if Dyna-Glo IR6PMDG-1 pilot light goes out when I release the knob?
    • J
      jennifer24Aug 1, 2025
      If the ODS/pilot light of your Dyna-Glo Heater lights but the flame goes out when you release the control knob: * Ensure the control knob is fully pressed in. * After the ODS/pilot lights, keep the control knob pressed in for 30-60 seconds. * Make sure the equipment shutoff valve is fully open. * Check the thermocouple connection and hand tighten it until it is snug, then tighten it an additional ¼ turn. * The thermocouple may be damaged and require replacement. * Inlet gas pressure may be too high; contact your gas supplier to check and adjust the inlet pressure.
  • N
    nschwartzAug 5, 2025
    What to do if Dyna-Glo IR6PMDG-1 Heater burner won't light after pilot is lit?
    • A
      Adrian WhiteAug 5, 2025
      If the burner(s) on your Dyna-Glo Heater do not light after the ODS/pilot is lit: * The thermostat setting may be too low; turn the thermostat knob to a higher setting. * The burner orifice may be clogged.
  • M
    Michael JonesAug 9, 2025
    How to fix a Dyna-Glo IR6PMDG-1 Heater when there is no spark?
    • C
      Cindy McdonaldAug 9, 2025
      If there is no spark at the ODS/pilot when the ignitor is pressed on your Dyna-Glo Heater, it could be due to several reasons: * The ignitor electrode may be positioned wrong or broken, consider replacing the ODS. * The ignitor electrode might not be connected to the ignitor cable, consider replacing the ignitor cable. * The ignitor cable could be pinched or wet; free the cable if pinched and keep it dry. * The ignitor cable may be damaged, consider replacing it. * The piezo ignitor or ignition module could be bad, consider replacing it. * The battery might be bad, consider replacing it.
  • C
    collinschristineAug 13, 2025
    Why does my Dyna-Glo Heater smell?
    • C
      Colleen BergerAug 13, 2025
      If your Dyna-Glo Heater produces unwanted odors, here are a few possible reasons: * The heater may be burning vapors from paint, hair spray, glues, etc. Ventilate the room and stop using odor-causing products while the heater is running. * There could be a gas leak. Locate and correct all leaks. * If you are using Propane /LP models, there may be a low fuel supply. Refill the supply tank.
  • K
    khernandezAug 17, 2025
    Why does my Dyna-Glo IR6PMDG-1 smell like gas when it's off?
    • A
      Andrew CarterAug 18, 2025
      If you notice a gas odor from your Dyna-Glo Heater even when the control knob is in the OFF position: * There may be a gas leak. Locate and correct all leaks. * The control valve might be defective.
  • J
    Jonathan SimpsonAug 22, 2025
    Why is the flame on my Dyna-Glo IR6PMDG-1 Heater yellow?
    • C
      cynthia91Aug 22, 2025
      If you observe a high yellow flame during burner combustion in your Dyna-Glo Heater: * There might not be enough air. Check the burner for dirt and debris and clean it if necessary. * The gas regulator could be defective and need to be replaced.

Summary

Safety Information and Guidelines

General Safety Warnings and Precautions

Critical warnings for safe operation, handling, and preventing hazards like fire or explosion.

Gas Safety and Carbon Monoxide

Information on detecting gas leaks and understanding carbon monoxide poisoning risks.

California Proposition 65 Warnings

Chemical exposure warnings mandated by California law regarding cancer and reproductive harm.

Installation and Usage Guidelines

Safety rules for installation, operation, and adherence to local codes.

Installation and Setup Procedures

Preparing for Installation and Unpacking

Steps for preparing the installation, including unpacking and verifying contents.

Ventilation and Airflow Requirements

Details on providing adequate air for combustion and ventilation for different space types.

Mounting, Clearances, and Bracket Attachment

Guidelines for heater location, minimum clearances, and attaching the mounting bracket.

Gas Supply Connection and Leak Testing

Instructions for safely connecting the gas supply and performing leak tests.

Operation and Maintenance

Lighting and Operating the Heater

Step-by-step instructions for lighting the pilot and operating the heater.

Heater Controls and Settings

Explanation of control knob positions, thermostat settings, and turning the appliance off.

Burner and Pilot Inspection

Guidance on inspecting pilot flame and burner flame patterns for correct operation.

Cleaning and Maintenance Procedures

Instructions for cleaning ODS/pilot, burner, air passageways, fan, and exterior.

Troubleshooting and Support

Troubleshooting Common Problems

Solutions for common issues like ignition failure, unit shutdown, gas odors, and fan problems.

Replacement Parts Information

Identification and ordering information for replacement parts.

Warranty and Registration

Details on product warranty coverage and the registration process.

Dyna-Glo IR6PMDG-1 Specifications

General IconGeneral
BrandDyna-Glo
ModelIR6PMDG-1
CategoryHeater
LanguageEnglish

Related product manuals