EasyManua.ls Logo

Dyna-Glo Pro - User Manual

Dyna-Glo Pro
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:30 a.m. – 4:30 pm CST, Monday – Friday
or email us at customerservice@ghpgroupinc.com
www.ghpgroupinc.com
USER’S MANUAL AND OPERATING INSTRUCTIONS
C US
PROPANE
CONSTRUCTION HEATER
GENERAL HAZARD WARNING
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH
THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS,
OR DAMAGE FROM THE HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, CARBON
MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD
USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION
MANUAL, LABELS, ETCETERA, CONTACT THE MANUFACTURER.
CONSUMER: Retain this manual for future reference.
50-10-104 Printed in China Rev. 2013-06-05
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
RMC-FA40DGD (40,000 BTU/HR, FORCED - AIR)
RMC-FA50DGD (30,000/50,000 BTU/HR, FORCED - AIR)
RMC-FA60DGD (30,000/60,000 BTU/HR, FORCED - AIR)
RMC-FA100DGD (70,000/100,000 BTU/HR, FORCED - AIR)
RMC-FA125DGD/LPFA125DGD (70,000/125,000 BTU/HR, FORCED - AIR)
RMC-FA150DGD (120,000/150,000 BTU/HR, FORCED - AIR)
RMC-FA40/DGP/DGP-01 (40,000 BTU/HR, FORCED - AIR)
RMC-FA50/DGP/DGP-01 (30,000/50,000 BTU/HR, FORCED - AIR)
RMC-FA60/DGP/DGP-01 (30,000/60,000 BTU/HR, FORCED - AIR)
RMC-FA100/DGP/DGP-01 (70,000/100,000 BTU/HR, FORCED - AIR)
RMC-FA125/DGP/DGP-01 (70,000/125,000 BTU/HR, FORCED - AIR)
LPFA125H/LPFA125H-01
RMC-FA150/DGP/DGP-01 (120,000/150,000 BTU/HR, FORCED - AIR)
Dyna-Glo™DELUX
MODELS:
Dyna-Glo™Pro
MODELS:
ANS Z83.7-2011 CSA 2.14-2011
Adequate ventilation must be provided.
FA40DGP-01
FA60DGP/DGP-01 LPFA125H/H-01

Questions and Answers

  • J
    Johnny LongAug 8, 2025
    What to do if my Dyna-Glo Pro quits while running?
    • B
      Bethany ScottAug 8, 2025
      If your Dyna-Glo Heater stops running, it could be due to several reasons. The internal temperature might be too high, causing the limit switch to shut down. Ensure the heater's output isn't restricted by obstructions. Additionally, a damaged control valve or a build-up of dust or debris inside the heater could be the cause. Consider replacing the control valve and cleaning the inside of the heater.
  • G
    Grace YatesAug 18, 2025
    Why Dyna-Glo Heater will not fire?
    • K
      Kimberly HartmanAug 18, 2025
      If your Dyna-Glo Heater won't ignite, it could be due to several reasons related to the ignition system. First, check the ignitor wire for looseness and re-attach or tighten it. Also, verify the spark module and replace it if necessary. Ensure that the spark gap is set correctly according to the specifications. Finally, a bad electrode might be the cause, so consider replacing the spark plug.
  • M
    Misty JohnsAug 27, 2025
    How to fix a Dyna-Glo Heater when the fan does not turn on?
    • D
      Dr. Allison Martin DVMAug 27, 2025
      If the fan on your Dyna-Glo Heater isn't turning on after making an electrical connection, there could be several reasons. First, ensure there is electric power reaching the heater by checking the current to the outlet. Inspect the heater housing for damage and make sure there are no obstructions to the fan. If the fan blades are bent, straighten them to match the others. If none of these steps work, the fan motor may be defective and require replacement.

Summary

Product Information and Safety Guidance

General Hazard Warning

Critical warnings about potential hazards like fire, explosion, and injury from heater use.

Model Information

Lists the available Dyna-Glo™ DELUX and Dyna-Glo™ Pro heater models.

Introduction and Specifications

Overview of the manual's content and initial specifications.

General Safety Instructions

Safety guidelines for operating the heater safely and preventing accidents.

Product Features

Highlights key functionalities and design aspects of the heater.

Unpacking Heater

Instructions for safely removing the heater from its packaging.

Technical Specifications

Technical details and operational parameters of the construction heater.

Operation and Maintenance Procedures

Information on Propane Gas Cylinders

Guidance on propane tank size, capacity, and requirements for safe operation.

Installation to Propane Gas Tank

Step-by-step instructions for connecting the heater to a propane gas tank.

Refilling the Propane Gas Tank

Procedures for safely refilling propane gas tanks for the heater.

Leak Checking

Methods for detecting gas leaks in connections using soap solution.

Lighting Instructions

Procedures for safely starting the heater's burner and ignition system.

Shutdown Instructions

Steps to safely turn off the heater and disconnect power.

Maintenance Instructions

Guidelines for cleaning and upkeep to ensure heater longevity and safety.

Troubleshooting and Parts Information

Troubleshooting

Common problems and their solutions for the propane construction heater.

Wiring Diagrams

Electrical schematics illustrating the heater's internal connections.

Replacement Parts List

A comprehensive list of parts available for replacement, with item numbers.

Warranty and Registration

Limited Warranty

Details of the manufacturer's warranty coverage for defects and duration.

Warranty Registration

Instructions and process for registering the heater's warranty with the manufacturer.

Dyna-Glo Pro Specifications

General IconGeneral
BrandDyna-Glo
ModelPro
CategoryHeater
LanguageEnglish