Fig 13
SPEED HANDLE
HIGH-PRESSURE FUEL PIPE BLET
OPERATING THE DIESEL GENERATOR
2-6 Proper operation of the generator set
2-6.1 Operating the diesel engine
1. Pre-heat the diesel engine for 3 minutes under
no load conditions.
2. First check the height of the lubricating oil level, if
it is low, refill it. Our diesel engines are equipped
with an alarm system that will notify you if the oil
pressure is too low. The alarm system will shut
down the engine if the oil pressure is too low.
3. Do not adjust the speed limit regulation bolt or
the fuel adjustment bolt. These bolts have been set
by the factory already, changing them will affect the
properties of the engine performance.
2-6.2 Checks during engine operation
1. Check to see if there are abnormal noises.
2. Check to see if the performance is good or bad
3. Check the color of the exhaust gases (whether it is too black or too white). If
any of these conditions exist, stop the engine and find the cause of the
problem. If no problems are found, please contact your local dealer or our
nearest company branch.
2-7 Loading
2-7.1 Load conditions
Exert loads in accordance with the specified parameters
2-7.2 Applying Load to your Generator
After generator is started, push circuit breaker to ON position and you should
read 120V in voltage meter when voltage selector is set for 120V output or
240V in voltage meter when voltage selector is set for 120V/240V output.
When applying loads to generator, make sure to apply loads in order. Apply
larger load onto the generator first. If the generator labors great with applied
load, smaller load can then be added. Never overload generator. Otherwise,
generator will black smoke or circuit breaker will be stripped. In this event,
decrease the number of small loads until generator labors normally. Please see
the technical specifications of generator for your reference. If the indication of
the voltage meter is too high or too low, adjust the engine speed (capacitor
used for brushless alternator) accordingly. Special skills are required to perform
speed adjustment. An authorized professional is recommended to perform this
work. If there are problems, stop the generator immediately and fix the issue.